Step 11
Installation Of Main
Remote Control
• Detach the fitting bracket from Main
remote controller by sliding it down.
• Attach the fitting plate to wall.
• Install conduit inside of wall in
advance and secure the wiring box.
• Pass remote controller cables
through conduit.
• Then pass the cables through the
hole of the fitting bracket and pull
them out.
• Attach the fitting bracket with screws
adjusting the screw hole to the wiring
box.
• Connect the remote controller
cables to the terminal for the remote
controller of PCB.
• If controllers are installed, the
maximum temperature setting will
still be 50°C.
Wiring box
Part No: IG090701
Version: B
Installer's Guide – Endurance six™
Installation Guide
Slot
Terminal
Bad examples
Chemicals
Do Not
Main Remote Control
Model CMR-2252
Remote controller
Remote controller
fitting bracket
Hook
7