Maintenance
Replacement
1. Inspect the fluid packing adjustment screw
for wear.
2. Place one fluid seal, two o-rings, and the fluid
seal front at the tip of the fluid packing tool
and gently slide the tool into the fluid tube
(See Figure 17). Firmly seat the packing.
3. Next, using the same technique, insert the
brass fluid seal spacer (See Figure 18).
4. Again, using the same technique, place the
second fluid seal and two o-rings into the
fluid tube (See Figure 19).
5. Start the packing adjustment nut into the
body by hand. Tighten the fluid packing nut
until it is flush with its stainless steel housing
(See Figure 20).
6. Lubricate the fluid needle as indicated in
figure 6 and reinstall the trigger housing,
along with the fluid needle and trigger
piston.
7. Replace the fluid tip using the DUX 10mm
fluid tip driver.
NOTE: See page 12 to view order of packing
components.