Auscision 442 Class Bedieningshandleiding - Pagina 4

Blader online of download pdf Bedieningshandleiding voor {categorie_naam} Auscision 442 Class. Auscision 442 Class 9 pagina's.

Quick Start Guide
Care has been taken in order for your model to perform straight out of the packaging. In general it
has been programmed to ESU Loksound's V5 Decoder default values. As modellers we all have
different ideas and preferences as to how our models perform. Should you wish to further adjust how
your model performs, the following is a quick start guide to some of the primary settings required to
do so.
Excerpts from the ESU Loksound V5 and Lokprogrammer references are included in the description
and are as follows. (Refer to the V5 Decoder Manual, the Lokprogrammer Manual or your DCC
systems programming section for full programming details)
The Default Locomotive Address for your 442 class model is 3.
In order to change the locomotive address, refer to chapter 9.1, 9.2 'Address Settings' of the ESU
V5 Decoder Manual. Individual DCC controller systems may also have a programme track output
and function available for this purpose.
Decoders operating within a DC operating system will function as per ESU's default DC settings.
For further detail also refer to the DC notes contained within our 48 class operating information
document found here:
http://www.auscisionmodels.com.au/PDFs/Auscision%20HO%20Scale%2048-
830%20class%20DCC%20Operating%20Information%20v4.pdf
Motor Auto Tune Procedure
Should you encounter any running performance issues the following Auto Motor Tune procedure may
help resolve the problem.
This feature will automatically adjust the Motors Back-EMF in most cases. This is not meant to be a
"cure all" solution. In most cases this will be all that is required, however there still may be the need to
perform some manual adjustments.
In order to use this automatic adjustment you will first need to place your locomotive on a section of
track paying attention to the set direction of travel. Set CV 54 to a value of 0. Activate function F1. (Be
sure to have plenty of clear space ahead of your locomotive. Allow 2 metres of available track) Your
locomotive will quickly take off at full speed and then stop while reading the motor responses. This will
automatically set the motor values required in CVs 52, CV 53, CV 54, and CV 55. From here you can
make any other manual adjustments if needed.
Refer Loksound V5 manual, chapter 11 for full motor adjustment details.
Minimum and Maximum Speeds
As default, the decoder will automatically detect the user's controller speed step settings, with the
controller using 14, 28 or 128 steps (28 being common).
Default is the Exponential 1 28 step speed table as per the graph below utilising minimum and
maximum speed settings.
Defaults are CV2 =3 (minimum speed value) and CV5 = 255 (maximum speed value).
Auscision 442 Class Operating Information (v3)
Page 4 of 9