Auscrown Y028NGWF-S Handleiding voor installatie en gebruik - Pagina 4
Blader online of download pdf Handleiding voor installatie en gebruik voor {categorie_naam} Auscrown Y028NGWF-S. Auscrown Y028NGWF-S 11 pagina's. Duckbill stockpot burner with flame failure safety device
PREPARE TO ASSEMBLE THE APPLIANCE
Check for damage on the appliance. If damage occurs, please contact Austcrown or your dealer. Do not use
a damaged appliance.
WARNING! It may hazardous to attempt to use a damaged appliance.
Positioning the Appliance
Only use the appliance in well ventilated areas.
CLEARANCE: The appliance must be sited with at least a 1000 mm gap between both sides (to combustible
surfaces), from the front and the rear of the appliance and at least 2700 mm from the trivet of the appliance
and any combustible or non-combustible materials above the appliance.
When the appliance is assembled abutting a side or rear wall, the wall must be of non-combustible material.
If surrounding walls are constructed with a combustible material, refer AS/NZS5601.1 for information on the
clearance required.
If the appliance is to be installed adjacent (next to) another appliance i.e. Y028NGWF-S next to another
Y028NGWF-S, then a minimum clearance of 200 mm must be maintained between appliances. This
clearance is to accommodate access to the gas connection fittings and to facilitate cleaning.
The appliance must be used on a level, stable, non-flammable surface when in use. This appliance is
intended for commercial use only.
It is important that the ventilation openings of the appliance are not obstructed. The appliance should be
protected from direct draughts.
The appliance should not be positioned or protected against direct penetration by any trickling water (e.g.
rain).
If the appliance is installed outdoors, a proper shelter with good ventilation should be used to protect the
appliance from draughts and rain. Some examples of shelters are shown below,
IMPORTANT: The dimension and building materials of the shelter must meet the requirements mentioned
above, or contact your gas authorised person/local Gas Authority for information on clearances and material
required.
DIAGRAMMATICAL REPRESENTATION OF OUTDOOR AREAS note this page and the next page
This appliance shall only be used in an above ground open-air situation with natural ventilation, without
stagnant areas, where gas leakage and products of combustion are rapidly dispersed by wind and natural
convection. Any enclosure in which the appliance is used shall comply with one of the following:
An enclosure with walls on all sides, but with no overhead cover (see figure 1).
Fig. 1
AC-R2-001
Page 4