Electric Lock Connection
Up to 2 x Electric locks can be connected and opened independently. Note: both
locks must be the same type, i.e. 2 of Power-on-to-unlock or 2 of Power-off-to-
unlock
Lock/s can be powered from Door Station if:
1. Electric lock is 'Power-on-to-unlock'
2. The lock is 12V, and holding current is less than 250mA
3. The lock control is not timed from Exit Button (EB)
The ' Unlock Mode' Parameter would be 0 (default, no need extra
programming)
connect one lock
1 2 3
Connect one lock
Jumper position in
BUS
PL
S1+
EB
*
Automated Gates and Magnetic Locks
1. Connect low voltage box of the gates according digram below
2. Additional power supply for Magnetic lock according lock specs
The ' Unlock Mode' Parameter for 'Power-on-to-unlock' would be 0 (default, no
need extra programming)
The ' Unlock Mode' Parameter for 'Power-off-to-unlock' would be 1 (needs
extra programming via monitor "Installer Setup")
2-3
S2+
S-
LOCK
connect two locks
1 2 3
Connect two locks
Jumper position in
2-3
BUS
PL
S1+
1
ST
EB
*
2
EB
nd
*
S2+
S-
2
nd
LOCK
1
ST
LOCK