Datasensor S62-PA-5-M11-PP Gebruiksaanwijzing - Pagina 4

Blader online of download pdf Gebruiksaanwijzing voor {categorie_naam} Datasensor S62-PA-5-M11-PP. Datasensor S62-PA-5-M11-PP 4 pagina's.

S62-PL...M Laser
Background suppression
INSTRUCTION MANUAL
CONTROLS
OUTPUT LED (yellow)
The yellow LED ON indicates the output status: N.O. closed and N.C. open.
POWER ON LED (green)
The green LED ON indicates the sensor powering status and laser emission
presence.
DISTANCE ADJUSTMENT TRIMMER (ADJ.)
The multiturn trimmer with clutch (6 turn) adjusts the suppression distance
through the mechanical variation of the optic triangulation angle.
The operating distance increases rotation the trimmer shaft in a clockwise
direction.
Please refer to "SETTING" paragraph for the correct use procedure.
POSITION INDICATOR
This indicator has a scale numbered from 1 to 6 that allows the precise
adjustment of the suppression distance on the entire operating range.
Please refer to "SETTING" paragraph for the correct use procedure.
INSTALLATION
The sensor can be positioned by means
of the three housing's holes using two
screws (M4x25 or longer, 1.5 Nm
maximum
tightening
torque)
with
washers.
Various orientable fixing brackets to
ease
the
sensor
positioning
are
available
(please
refer
to
the
accessories
listed
in
the
general
catalogue).
The operating distance is measured from the front surface of the sensor
optics.
The M12 connector can be oriented at two different positions using the
specific fastening spring and rotating the block to 180°.
CONNECTIONS
M12 connector
Power supply:
Ripple:
Consumption
(output current excluded):
Outputs:
Output current:
Output saturation voltage:
Response time:
Switching frequency:
RED LASER (λ = 645...665nm): Class 2 EN 60825-1 (1994), Class II CDRH 21 CFR PART 1040.10
Emission type:
Pulsed emission: pot. max ≤ 5mW; pulse duration = 5µs; frequency = 14KHz (mod. M01) / 10KHz (mod. M11)
Focalisation point :
Spot dimension:
< 0.2 mm (at 60 mm)
Operating distance (typical values):
Adjustment:
4 turns distance adjustment trimmer
Difference (90% white/ 4% black):
Hysteresis (90% white):
Indicators:
Functioning temperature:
Storage temperature:
Insulating strength:
Insulating resistance:
Ambient light rejection:
Vibrations:
Shock resistance:
Housing material:
Lens material:
Mechanical protection:
Connections:
Weight:
Suppression distance setting
1. Object detection
Position object to detect in front of the sensor at the distance required.
Turn distance adjustment trimmer (ADJ) to minimum: yellow LED OFF and
green LED ON.
Rotate trimmer in a clockwise direction until the yellow LED and green LED
turn ON. Object detection condition (A status of position indicator).
A
2. Background suppression
Remove object and ensure that the background is in front of the sensor:
yellow LED OFF and green LED ON.
Rotate trimmer in a clockwise direction until the yellow LED and green LED
turn ON: background detection condition (B status of position indicator).
B
The trimmer reaches maximum level with yellow LED OFF if the background
is outside the operating range.
TECHNICAL DATA
S62-PL-M01...
S62-PL-M11...
10 ... 30 VDC
2 Vpp max.
30 mA max
PNP or NPN N.O. / N.C.; 30 VDC max. (short-circuit protection)
100 mA (overload and overvoltage protection)
≤ 2 V
140 µs
3.5 kHz
60 mm
< 0.4 mm (at 150 mm)
30...150 mm
50...350 mm
6 turns distance adjustment trimmer
< 4 % (see DETECTION DIAGRAM)
< 1 %
OUTPUT LED (YELLOW) / POWER ON LED (GREEN)
-10 ... 55 °C
-20 ... 70 °C
500 Vac 1 min., between electronics and housing
>20 MΩ 500 Vdc, between electronics and housing
According to EN 60947-5-2
0.5 mm amplitude, 10 ... 55 Hz frequency, for each axis (EN60068-2-6)
11 ms (30 G) 6 shock for each axis (EN60068-2-27)
ABS
PMMA window; PC lens
IP67
M12-4 pole connector
40 g. max.
SETTING
Rotate trimmer in an anticlockwise direction until yellow LED turns OFF
and green LED ON: condition where background is outside operating
range (C status of position indicator).
3. Setting and control
Rotate trimmer in an anticlockwise direction until the indicator reaches
an intermediate point between position A and C.
If position A and C are close to each other, leave trimmer on position C.
The sensor is now ready to function correctly and in stable conditions.
DETECTION DIAGRAM
200 µs
2.5 kHz
150 mm
11
6.18
10.7
OUTPUT LED
POWER ON LED
SAFETY PRECAUTIONS
All the electric and mechanical safety regulations have to be respected during
sensor functioning.
The sensor has to be protected against mechanical damage.
Apply the labels supplied in a visible position near the laser emission beam.
C
Do not stare directly into the laser beam!
Do not point the laser beam towards people!
Eye irradiation superior to 0.25 seconds is dangerous. Please refer to the
Class 2 Standard (EN60825-1).
These sensors can not be used for safety applications!
EX-II-3-D T6
Temperature class:
Max. Power consumption:
Max. Internal capacitance:
Internal inductance:
DECLARATION OF CONFORMITY
We DATASENSOR S.p.A. declare under our sole responsibility that these products are conform to the
2004/108/CE, 2006/95/CE Directives and successive amendments.
WARRANTY
DATASENSOR S.p.A. warrants its products to be free from defects.
DATASENSOR S.p.A. will repair or replace, free of charge, any product found to be defective during the
warranty period of 36 months from the manufacturing date.
This warranty does not cover damage or liability deriving from the improper application of
DATASENSOR products.
DATASENSOR S.p.A. Via Lavino 265
40050 Monte S. Pietro - Bologna - Italy
Tel: +39 051 6765611
Fax: +39 051 6759324
http://www.datasensor.com
DATASENSOR S.p.A. cares for the environment: 100% recycled paper.
DATASENSOR S.p.A. reserves the right to make modifications and improvements without
prior notification.
DIMENSIONS
50
18
42
4.7
RECEIVER
EMITTER
6
14
M12
Ø15
11
18.4
DISTANCE ADJUSTMENT TRIMMER
POSITION INDICATOR
mm
T6 (<85°C)
800 mW at 30 Vdc
100 pF
negligible
826003241 Rev.B