Moving of the Unit.
When moving the Air Compressor, the
forklift or hand lift forks go under the Unit
from the directions as indicated.
Please be advised that care must be taken
when moving and positioning the Units as
they are top heavy.
Location of the Unit.
Items to consider when installing the Unit are as
follows:
The Unit should be located in a dry, clean, cool,
dust free, and well ventilated area. If possible,
the Compressor should be located in a
separate room or area, away from the general
operations of the shop.
Allow approximately a minimum of 18" (458mm)
around and 3 feet (915mm) above the Unit for
easy access to the various sides, this being for
both the proper ventilation of the Unit and ease
of servicing.
Ensure that the floor under the Unit is smooth,
level and capable of bearing the weight of the
Compressor. The Compressor must sit
squarely on the floor.
If installed in a compressor room, ensure that the
room is adequately ventilated. (One
Horsepower produces approximately 2500
BTU/HR.)
The ambient temperature should be between
10° C and 40° C (50° F to 104° F).
Installation – Mechanical
Many common Compressor problems can be
attributed to the location or installation of the Unit.
Make sure the Unit is in a suitable location, and
installed correctly.
- 6 -
If installing the Unit on a mezzanine, ensure that
the structure can safely support the weight of
the Unit. As well, the sound level of the Unit
may increase due to the harmonics created by
the structure; use Vibration Pads to lessen this.
The Compressor must not be operated in
a confined area where the heat from the
Unit cannot readily escape.
A5-C