To choose the motorcycle battery type
1.
Disarm the DT201.
2.
Turn on the ignition.
3.
Within 10 seconds, press and hold both buttons on the remote control.
4.
After 3 seconds the DT201 will start to chirp loudly. Release the remote control buttons
after four chirps, if you miss the correct chirp wait for the alarm to exit programming
mode after the seventh chirp or turn off the ignition a loud chirp will be given to indicate
programming has been exited.
5.
The DT201 will bleep a specified number of times to indicate the current setting, the LED will
flash the current setting repeatedly.
6.
Press the Arm/Disarm or Programming button on the remote control to cycle through the
motorcycle battery options:
• Lead Acid (1 Bleep) (Default).
• Lithium (2 Bleeps).
7.
Turn off the ignition to exit programming and save the new setting a loud chirp will be
given. If the ignition is not switched off within 30 seconds the DT201 will give a loud chirp
and the currently selected setting will be stored.
To reset the DT201 to the default settings
1.
Disarm the DT201.
2.
Turn on the ignition.
3.
Within 10 seconds, press and hold both buttons on the remote control.
4.
After 3 seconds the DT201 will start to chirp loudly. Release the remote control buttons
after five chirps, if you miss the correct chirp wait for the alarm to exit programming mode
after the seventh chirp or turn off the ignition a loud chirp will be given to indicate
programming has been exited.
5.
The DT201 will bleep once and the LED repeatedly once every three seconds.
6.
Press the Arm/Disarm button on the remote control once, the DT201 will bleep twice and
the LED will double flash repeatedly
7.
Press both buttons on the remote control to save the default settings a loud chirp will be
given and the alarm will exit programming.
To add a new remote control
1.
Disarm the DT201.
2.
Turn on the ignition.
3.
Within 10 seconds, press and hold both buttons on the remote control.
4.
After 3 seconds the DT201 will start to chirp. Release the remote control buttons after six
chirps, if you miss the correct chirp wait for the alarm to exit programming mode after
the seventh chirp or turn off the ignition a loud chirp will be given to indicate
programming has been exited.
5.
The DT201 will give a single bleep and flash the LED repeatedly once every three
seconds.
6.
Press either button on the current remote control two bleeps will be given and the LED
will double flash repeatedly.
7.
Press both buttons together on the remote control, the DT201 will bleep twice and the LED
will extinguish