Aussie Pumps BB100 Hire Series Bedienings- en onderhoudshandleiding - Pagina 16

Blader online of download pdf Bedienings- en onderhoudshandleiding voor {categorie_naam} Aussie Pumps BB100 Hire Series. Aussie Pumps BB100 Hire Series 16 pagina's. High pressure blasters

Aussie Pumps BB100 Hire Series Bedienings- en onderhoudshandleiding
OVER SPEEDING
Do not operate machine at over 3200rpm (engine speed). Over speeding can cause serious pump
damage.
EXCESSIVE BYPASS
Do not run on excessive by-pass. Switch machine off within two minutes of ceasing operation as
excessive by-pass can cause heat build up in pump and subsequent damage. Excessive bypass running
voids warranty.
HIGH PRESSURE SETTING
The high pressure pump is factory set to operate at its rated pressure. DO NOT ADJUST. Tampering
with the pressure regulator will void warranty and can be DANGEROUS.
CHECK NOZZLE MONTHLY
If pressure drops off check nozzle for wear. Nozzles should be replaced on a regular basis (every month
for machines in regular use, every three months for machines used intermittently). Using the machine
with the incorrect nozzle size or worn nozzle will void warranty and can be DANGEROUS to the operator.
PRESSURE CLEANER DAILY CHECK LIST
Check pump oil level
Check engine oil level
Check nozzle for wear
Check all high pressure components for leaks:
gun/lance
HP hose
all fittings
Check water filter and clean if necessary
Check unloader, safety valve and thermal dump for leaks
THREE MONTHLY REGULAR SERVICE
All professional machines need to be thoroughly serviced every three months. The service involved should
include the engine manufacturer's recommendations (see separate Engine Manual) and the following;
Change pump oil
Change gearbox oil (if applicable)
Check filter for foreign debris
Check unloader, safety valve and thermal dump for leaks
Check all HP components for leaks: Gun/lance, HP hose and all fittings
Replace nozzles
Check gearbox to engine key for wear, if key is worn see your local Aussie Eco Clean Service
Department. NB Damage generated by worn keys is not covered by warranty.
To maintain the Bertolini pump warranty (three years from date of purchase), the pump must be serviced by an
authorised service agent every six months. Contact Aussie for your nearest agent.
LOOK AFTER YOUR MACHINE AND IT WILL LOOK AFTER YOU!
Aussie HP Accessories ... making light work of cleaning chores
WEAR PROTECTIVE GOGGLES & CLOTHING!
WARNING
SIX MONTHLY REGULAR SERVICE
Australian Pump Industries Pty Ltd
7 Gladstone Road, Castle Hill NSW 2154
Ph: (02) 8865 3500 Fax: (02) 9894 4240
www.aussiepumps.com.au [email protected]