The Sentry 900 is capable of reading both low and
high powered ERT modules from approximately 1
foot away from the meter.
REAdInG ModuLES In hIGh SEnSITIVITy ModE

Specifications

_________________
Sometimes it may be desirable to read modules
from farther away than the normal 1-2 foot range.
Operating Temperature:
The Sentry 900 is equipped with a high sensitiv-
-20º to 70º Celsius
_________________
ity mode that will allow modules to be read at a
greater distance than possible in normal mode.
Storage Temperature:
Modules can be read up to 25 feet away depending
-40º to 85º Celsius
on the environment when the Sentry 900 is in high
_________________
sensitivity mode.
Operating Humidity Range:
5- 95% non-condensing
Note: When using high sensitivity mode, care must
_________________
be taken to ensure that you are able to read the
Module Reading Queue:
intended modules. The Sentry 900 is capable of
reading only 10 meters simultaneously, so in areas
10 readings simultaneously
_________________
of dense module concentration it may be difficult to
capture the correct reading. High module density
Receiver Sensitivity:
will require the use of normal sensitivity to isolate
Normal Sensitivity Mode,
the correct module.
High Sensitivity Mode
_________________
To place the Sentry 900 into high sensitivity mode,
Weight:
depress the uP button once you are already in the
9.5 ounces
receive mode. you will see the normal antenna icon
_________________
on the screen as well as an 'h' icon beside the an-
Dimensions:
tenna to indicate you are in high sensitivity mode.
8.9" x 3.6" x 1.5"
To return to normal sensitivity mode, press the
(without cover)
down button. The 'h' icon will disappear and the
_________________
'0' icon will reappear to indicate you are in normal
Cover Colors:
sensitivity mode.
Red, Blue, Yellow, Green,
REAdInG ModuLES REquIRInG
Grey
_________________
A wAkE-uP TonE
Power Supply:
Some modules require a wake-up tone in order
to begin to transmit. These include gas modules,
Three AA Batteries
water modules and older electric module such as
(included)
the ERT 40 and ERT 45 series. In order to transmit
a wake-up tone, place the unit in the receive mode
by pressing the
antenna icon appears press And RELEASE the
7 Ross Cannon Street
An Austin International Company
VIEwInG CAPTuREd REAdInGS
once ERT readings have been captured by
the Sentry 900, the readings can be viewed by
scrolling through the stored values using the uP
and down buttons. The Sentry 900 can re-
ceive and store up to 10 messages simultane-
ously. once the 10 slots are filled, the Sentry
900 will overwrite the slots when new ERT
devices are detected. Values displayed
include the record number (0-9), ERT
Type, Electric tamper count, physical
tamper count, module serial number
and meter reading.
CLEARInG SToREd REAdInGS
Stored ERT readings can be
cleared from the Sentry 900's
memory by simultaneously push-
ing the uP and down buttons.
RECEIVE ON/OFF
york, SC 29745
Phone (803) 628-0035
POWER BUTTON
beside the antenna icon (not the '0" that indicates
normal sensitivity mode) to indicate the particular
wake-up tone that the Sentry 900 is using. The an-
tenna icon will flash for 2-3 seconds to indicate that
a wake-up tone is being transmitted. The wake-up
tone can be re-transmitted by pressing the
button again. The wake-up tone can be changed
from the Sentry 900's setup menu as described
later in the manual.
MEASuRInG ModuLE SIGnAL STREnGTh
The Sentry 900 is also capable of measuring the
relative signal strength of the module while it is
transmitting. In order to measure signal strength,
place the unit in the receive mode then press and
hold the
the Sentry 900 display will show a transmit symbol
then a number representing signal strength below
the module serial number (where the module read-
ing is normally displayed).
once the
returns to normal sensitivity mode and displays the
module reading once again.
Sentry 900 Set-Up
EnTERInG SET-uP ModE
In order to enter the Sentry 900's setup mode press
and hold the
button simultaneously. Instead of displaying the
normal start-up display, the Sentry 900 will display
the Tone icon and a number between 0-9.
SELECTInG ThE wAkE-uP TonE
with the unit Sentry 900 in set-up mode and the
'Tone' icon displayed press the
order to cycle through the available wake-up tones.
once you reach the correct tone press the
button to exit set-up mode.
SELECTInG ThE nuMBER oF dECIMALS To dISPLAy
Some ERT and AirPoint modules transmit decimals
as part of their reading. The Sentry 900 allows you
to either display the 2 decimals or to truncate the
decimals and only display whole numbers. with the
Sentry 900 in set-up mode, press the
to cycle through the various modules types: 02, 04,
05 or 08. Each type will have the option of select-
ing '0' or '2' which determines how many decimals
to display. once you have selected the number of
decimals to display for each module type, press the
POWER
button. once the
Fax (803) 628-0282
. A number will momentarily appear
button. when the module transmits
DOWN
button is released, the Sentry 900
DOWN
button then press the
DOWN
RECEIVE
button to exit set-up mode.
www.austininc.com
POWER
POWER
button in
POWER
or
UP