4PRO PET 5 Installatie, waarschuwingen en bedieningsinstructies - Pagina 2
Blader online of download pdf Installatie, waarschuwingen en bedieningsinstructies voor {categorie_naam} 4PRO PET 5. 4PRO PET 5 2 pagina's. Thermal expansion tanks
B
EFORE
P
I
RODUCT
NSPECTION
Visually inspect the product for any signs of damage that may have occurred during transportation. If the tank is dented,
bent or scratched, return the product to the original purchase point for replacement.
P
C
A
RE-
HARGE
DJUSTMENT
This expansion tank is shipped from the factory with a pre-charge of 40 PSI. Any adjustments to the factory pre-charge
must be done prior to initial tank installation and with 0 PSI pressure on the system. DO NOT ADJUST THE PRE-
CHARGE OF THE THE EXPANSION TANK WITH THE SYSTEM UNDER PRESSURE!
The expansion tank should be pre-charged to the incoming system water pressure but must not exceed 80 PSI. Failure
to properly adjust the pre-charge will shorten the life expectancy of the product
T
A
T
P
C
O
DJUST
ANK
RE-
HARGE:
Remove the protective cap from the air valve.
Check the tank pre-charge pressure using a standard tire pressure gauge.
If required add air to the tank using a manual bicycle tire pump until the proper pre-charge pressure is reached.
Replace the protective cap on the air valve.
I
NSTALLATION
L
OCATION
Select a location where a water leak will not cause prop-
erty damage and provides adequate means for water
drainage. This expansion tank and the associated piping
may in time leak. The manufacturer is not responsible for
any water damage that may occur in association with the
expansion tank installation.
Disconnect or shut off the electrical
WarninG
power source to the water heater.
Shut off the water supply to the system and remove all
water pressure from the system. Failure to follow these
instructions may result in serious injury or death and or
property damage.
The tank is designed to be supported by the system
piping. Make sure that there is adequate means of
supporting the system piping and if necessary add
strapping, brackets or pipe hangars.
DO NOT INSTALL THIS EXPANSION TANK IN THE
HORIZONTAL POSITION.
Install the expansion tank in the incoming water line to the
water heater between the water heater and the backflow
preventer or check valve (see Fig. 1). Adequate thread
sealant (pipe dope) must be added to ensure a leak free
installation.
I
NSTALLATION
fig. #1
Before turning on the water supply to the system, open a
hot water faucet to prevent any damage to the water
heater and remove air from the system piping. Turn on the
water supply and inspect the installation for water leaks
paying close attention to the connection between the ex-
pansion tank and the piping.
Follow the water heater manufacturer's instructions for
proper start-up of the heater and the system.
This expansion tank and the entire system must be checked annually by a qualified professional.
Visually examine the tank and its connection to the system piping looking for any signs of water leakage or corrosion on the
exterior of the tank or the connection.
If this expansion tank shows any visible signs of leaking, corrosion or rusting, the tank must be replaced
WarninG
immediately to avoid personal injury or property damage. Do not adjust the tank air pressure if there
are any signs of corrosion on the tank. Failure to follow these instructions may result in serious injury or death and or
property damage.
S
PECS/
.
M A T E R I A L S O F C O N S T R U C T I O N
.
Tank: 16 gauge cold rolled steel
.
Finish: Appliance quality paint for indoor or outdoor installation
.
Water chamber: 100% butyl rubber, lined with polypropylene
Connection: Stainless Steel
D I M E N S I O N S & C A P A C I T I E S
Max.
Volume
Acceptance
Model
(gallons)
Volume
(gallons)
PET 5
2.1
1
PET 12
4.8
2.5
Maximum working pressure 150 PSIG. Maximum working temperature, internal and external 200 degrees F. Tank pre-charge 40 PSIG.
NOTE: PET Series tanks are certified to NSF Standard 61 Domestic Hot, but are suitable for temperatures up to 200 degrees F.
C
A
M
AINTENANCE
D
IMENSIONS
.
Testing: High pressure, seam weld, helium, final
precharge check
.
.
Air valve: Brass valve with o-ring seal
Warranty: One year
Dimensions (inches)
System
Connection
(inches)
Diameter
Height
¾ MNPT
8
11.6
¾ MNPT
11
14.5
PET SERIES
B
Weight
(lbs)
5
10
Rev. 5.13