Frequency Response
Total Harmonic Distortion
Signal To Noise Ratio
Input Sensitivity (Program Inputs)
Input Impedance (Program Inputs)
Input Connection
Zone Mics: Line Level XLRs; Zone Control: 15 pin standard 'D' connector
Outputs
Zone Input
Power Sources
Power Consumption
Dimensions/Weight
Control Cable & Connector Requirements
ARCHITECTURAL AND ENGINEERING SPECIFICATIONS
The Zone Paging System shall consist of an 8 zone matrix switcher and up to 8 zone paging micro-
phones. The switcher shall have facilities to enable up to 4 program inputs to be assigned to any of the
8 outputs via simple front panel push buttons. The switcher shall include program select, program level,
mic level and master level controls for each zone. Additionally, any zone shall have the ability to be
removed from the paging function via front panel buttons. The switcher shall also include a bell tone
and evacuation tone as well as a defeatable pre-announce chime. An emergency input shall be provid-
ed on the rear panel.
The zone paging microphones shall have 8 zone buttons, each with a status LED, a zone page button,
all page button and a clear button. A busy LED shall be included on each zone microphone. One micro-
phone shall have overall priority, a second shall have secondary priority. All microphones shall have pri-
ority over the program sources.
The Zone Paging System shall be an Australian Monitor Installation Series PageNet88.
), 149 Beaconsfield Street, Silverwater, Sydney, NSW, 2128 Australia
ABN 78 001 345 482
Program Inputs: Dual RCA sockets with trim control;
Zone Outputs: 600 Ohm line level XLR (1.5V RMS)
AC: 240V - 50Hz or 110V - 60Hz (special order),
3 pin IEC connector; DC: 12-24V DC
88mm H x 480mm W x 200mm D (Chassis dimensions only). 6kg
Hartland HCE316 or equivalent;
15 pin standard 'D' connectors
Website: www.australianmonitor.com.au
50Hz - 15kHz (± 3dB)
0.1%
-70dB
100mV
22K Ohms
100mV
25 Watts (maximum)