THERMOMETER
There is a remote thermometer built into the front panel of
the device typ EKR for monitoring the stored water tempe-
rature.
The display value depends upon the temperature regulator
setting. Only with the adjustment knob at „Pos." and after
completion of the warm up process is the maximum display
value reached. For other regulator positions the pointer de-
flection is reduced accordingly.
ADJUSTMENT RANGE LIMITATION (EKR)
In order to avoid unintentional scalding caused by water
which is too hot, the adjustment range of the temperature
regulator can be limited to a maximum of 65°C. The device
must be electrically isolated from the grid at all poles. Set to
„Pos ". After opening the connection space, remove the
stop pin in that is located in a drilling in the back of the con-
trol panel and reinsert it into the hole with the long shaft in
front.
PREREQUISITES FOR OPERATION
The storage tanks must be used exclusively in accordance with the conditions specified on the rating pla-
te. In addition to national regulations and standards recognised in the laws, compliance with the connec-
tion conditions of the local electricity company and water supply works as well as the installation and
operation instructions is required.
The room where the device is operated must be free of frost. The device must be installed in a reasonably
expected location, i.e. if the device needs to be maintained, repaired or replaced, it must be readily acces-
sible. If the water is very hard, either of the following options is recommended: to connect a commercially
available standard descaling device upstream of the tank observe a maximum operating temperature of
approximately 65°C (setting "Pos. "). The bare-tube heat exchanger of the EKR series must be flushed
properly before the initial installation is performed. If the bare-tube heat exchanger is not used, the outer
tube ends must be sealed to prevent back-cooling. The drinking water quality must be appropriate to
ensure proper operation.
It is recommended to fit a water filter upstream of the device to keep the tank free of dirt and other par-
ticles.
Should a device, at the point of delivery, clearly display a malfunction, damage or other defect, this must
not be fitted, installed or used in the system. Subsequent complaints regarding devices with an obvious
defect which have been connected and installed are expressly excluded under the warranty and guaran-
tee.
Remote reading thermometer
7