BENDIX R-12DC Servicegegevens

Blader online of download pdf Servicegegevens voor {categorie_naam} BENDIX R-12DC. BENDIX R-12DC 8 pagina's. Relay valve with biased double-check
Ook voor BENDIX R-12DC: Handmatig (8 pagina's), Installatie-instructies (4 pagina's)

BENDIX R-12DC Servicegegevens
Bendix
R-12DC
®
PRIMARY
SERVICE
SUPPLY (2)
EXTERIOR BENDIX
(MODEL WITH 2 HORIZONTAL PORTS)
Figure 1 – Exterior Views
DESCRIPTION
The relay valve in an air brake system functions as a relay
station to speed up the application and release of the
brakes. The valve is normally mounted at the rear of the
vehicle in proximity to the chambers it serves. The valve
operates as a remote controlled brake valve that delivers
or releases air to the chambers in response to the control
air delivered to it from the foot brake valve.
PRIMARY
SERVICE
PORT
CAP SCREW
SEALING
RING
RELAY
PISTON
O-RING
EXHAUST
SEAT
SPRING
O-RINGS
RETAINING
RING
Figure 2 – Bendix
R-12DC
®
Relay Valve with Biased Double-Check
®
SECONDARY
SERVICE
DELIVERY
R-12DC
VALVE
®
®
COVER
EXHAUST
PORT
Relay Valve with Biased Double-Check Sectional View
®
EXTERIOR
R-12DC
®
(MODEL WITH
4 VERTICAL
DELIVERY PORTS)
EXTERIOR
R-12DC
®
(MODEL WITH 2
HORIZONTAL AND 2
VERTICAL DELIVERY
PORTS)
Bendix
R-12DC
®
reservoir or frame mounting. (See Figure 1). For ease of
servicing, the inlet/exhaust valve can be replaced without
the need for line removal.
SECONDARY
SERVICE PORT
RELAY
PISTON
VALVE
RETAINER
INLET
EXHAUST
VALVE
SPRING
VALVE
VALVE
relay valves are designed for either
®
GUIDE
DOUBLE-CHECK
DIAPHRAGM
1