Discharge
Optional "Ping" Tank
Line
Compressor
FIGURE 6A - SYSTEM DRAWING
DUTY CYCLE
The duty cycle is the ratio of time the compressor spends
building air to the total engine running time. Air compres-
sors are designed to build air (run "loaded") up to 25% of
the time. Higher duty cycles cause conditions that affect
air brake charging system performance which may require
additional maintenance. Factors that add to the duty cycle
are: air suspension, additional air accessories, use of an
undersized compressor, frequent stops, excessive leakage
from fi ttings, connections, lines, chambers or valves, etc.
Refer to Table A in the Troubleshooting section for a guide
to various duty cycles and the consideration that must be
given to maintenance of other components.
COMPRESSOR INSTALLATION
While the original compressor installation is usually com-
pleted by the vehicle manufacturer, conditions of operation
and maintenance may require additional consideration. The
following presents base guidelines.
DISCHARGE LINE
The discharge line allows the air, water-vapor and oil-vapor
mixture to cool between the compressor and air dryer or
reservoir. The typical size of a vehicle's discharge line,
(see column 2 of Table A in the Troubleshooting section)
assumes a compressor with a normal (less than 25%) duty
cycle, operating in a temperate climate. See Bendix and/or
other air dryer manufacturer guidelines as needed.
4
Air Dryer
Governor
(Governor plus Synchro valve
™
®
for the Bendix
DuraFlo
596
Compressor)
The Air Brake Charging System
compressed air for the braking system as well as other air
accessories for the vehicle. The system usually consists
of an air compressor, governor, discharge line, air dryer,
and service reservoir.
Optional Bendix
Oil Coalescing Filter
Service Reservoir
(Supply Reservoir)
The discharge line must maintain a constant slope down
from the compressor to the air dryer inlet fi tting or reservoir
to avoid low points where ice may form and block the fl ow.
If, instead, ice blockages occur at the air dryer or reservoir
inlet, insulation may be added here, or if the inlet fi tting is
a typical 90 degree fi tting, it may be changed to a straight
or 45 degree fi tting. Shorter discharge line lengths or
insulation may be required in cold climates.
While not all compressors and charging systems are
equipped with a discharge line safety valve this compo-
nent is recommended. The discharge line safety valve is
installed in the cylinder head (Tu-Flo
the compressor discharge port and protects against over
pressurizing the compressor in the event of a discharge
line freezeup.
THREAD
FIGURE 6B - DISCHARGE LINE SAFETY VALVE
supplies the
®
PuraGuard
®
QC
™
Reservoir Drain
®
550/750) or close to
HOLE