Blader online of download pdf Gebruiksaanwijzing voor {categorie_naam} AirCom DB110. AirCom DB110 4 pagina's. Back pressure regulator made of aluminium
If devices are connected to the pressure limiting valve, the setting of the pressure limiting valve needs to ensure that
no dangerous pressure can build up. The medium discharging from the outlet of the pressure limiting valve has to be
carried away in a defined manner.
When changing the type of gas, the pressure limiting valve should be purged sufficiently with inert gas.
3.2 Regulations and guidelines
The following regulations and guidelines must be observed in Germany on a case-by-case
basis:
-
Standards of prevention
-
Operating working materials
-
Guidelines for laboratories
-
Ordinance on Industrial Safety and Health
-
Data sheet "Dangerous substances"
4. Installation
4.1 Transport and packaging
When the pressure limiting valves are delivered, please check for possible transport damage or defects. The
connection openings of the pressure limiting valves may be closed for transport by caps to prevent dirt particles from
entering. Do not remove the caps until just before installation. In case of a later disassembly, the connection
openings need to be closed again before being put into storage or being transported. This can also be done
provisionally by a strip of adhesive tape that is taped over the opening.
The transport of the pressure limiting valve (e.g. sending to customer service) may be done only in a suitable sturdy
package.
4.2 Preparation
• Turn the adjusting screw (hand wheel, spindle, hexagon) on the pressure limiting valve anticlockwise until the
range spring is completely relaxed.
• Connect pressure limiting valve – connection threads have to match.
• To ensure the pressure limiting valve is in perfect working condition, all lines needs to be purged prior to
installation. Deposits and other foreign objects can cause damage to the valve seat, and thus interfere with the
regulating function or make it impossible. No lubricants may be used during installation. The pressure limiting valve
may soil and there is a risk of burning out if oxygen or nitrous oxide is used.
DB110 Pressure limiting valve
The pressure limiting valve has to be installed in the line in such a way that the medium flows in the direction of the
arrows stamped/adhered onto the housing (IN to OUT). Internal filters are only for the protection against possible
soiling during the installation. It is recommended to use external input pressure filters. All gaseous media should be
free of moisture to prevent icing of the pressure limiting valve at high flow rates.
4.3 Operating
The desired upstream pressure is set by turning the adjusting screw (hand wheel, spindle, hexagon). Turning
clockwise increases the upstream pressure, turning anticlockwise reduces the upstream pressure.
The general function of a pressure limiting valve is described in the following film.
Animation film pressure limiter
Fine adjustments should always be made in the direction of upstream pressure increase in order to reach the
precise setting point. These pressure limiting valves function with all media that are compatible with the specified
materials.