dymax 826 Gebruikershandleiding - Pagina 12
Blader online of download pdf Gebruikershandleiding voor {categorie_naam} dymax 826. dymax 826 20 pagina's. Disposable fluid path valve
Model 826 Dispensing Valve User Guide
12
Operating the Dispensing Valve
Figure 7. Stages of Valve Operation
Start Up
Dispense
Shut Off
Start Up
When the valve is off/unactuated, the pinching surface of the spring-closed Upper Piston
(Figure 7, A) prevents flow by collapsing the Tube (Figure 7, B). The Pinch Stop Adjusting Screw
(Figure 7, C) limits the amount of pinch, which limits the stress on the Tube, extends the tubing
life, and insures shot repeatability. The blunt Lower Piston (Figure 7, D) is held in its open
position by a spring. The Adjusting Screw (Figure 7, E), which determines the amount that this
piston will close the tubing when actuated, is set to a position that will allow approximately
50% tube closure.
Dispense
When the valve is on, the air moves the Upper Piston (Figure 7, A) back to the Adjustable Stop
(Figure 7, F). This stop controls the amount the tube opens, which in turn controls the rate of
flow through the tube. These actions, combined with nozzle size (if a nozzle is used), fluid
pressure, and the amount of time the 826 valve is open, governs the amount of fluid