Operating the Controller

Setting the Dispense Time

The digital timer on the front of the controller uses up and down arrows to set the
required dispense time. The time range is from 0.001 seconds to 9.999 seconds with a
settable resolution of .001 seconds.
Figure 4.
Front Panel
E
F
C
D
(A) Up Arrow - used to increase the present value at each digit.
(B) Down Arrow - used to decrease the present value at each digit.
(C) Mode - changes modes and setting items on the timer.
(D) Reset - used to reset the current count.
(E) Active Timing Value
(F) Current Preset Timing Value
(G) Left Toggle - used to switch the system between timed or untimed mode.
Timed Mode: hitting the center trigger toggle or foot switch will open the dispense valve
for the duration preset in the digital timer.
Untimed Mode: the valve will remain open for as long as the trigger or foot switch is held
down.
(H) Center Toggle - used to trigger the valve. Actuating the supplied foot switch
performs this same function.
(I) Right Toggle - turns the system's power on or off.
1 0
B
A
G
H
I