maintain batteries during prolonged periods of storage without
overcharging or damaging the battery.
6) The CT-3800 has four external holes for mounting. Mount the charger
in a desired location with equipped self-drill screws. It is important to
keep in mind the distance to the battery.
7) Following is the charger's technical specification:
AC Input
DC Output
Charger Type
Start Voltage
Housing Protection
Battery Type
Battery Capacity
Accessories Included
Ambient Temperature
CONNECTING TO THE BATTERY
1) Identify polarity of battery posts. The positive battery terminal is
typically marked by these letters or symbol (POS,P,+). The negative
battery terminal is typically marked by these letters or symbol (NEG,N,-).
2) Do not make any connections to the carburetor, fuel lines, or thin
metal parts.
3) Identify if you have a negative or positive grounded vehicle. This can
be done by identifying which battery post (NEG or POS) is connected to
the chassis.
4) For a negative grounded vehicle (most common): connect the RED
POSITIVE clamp / ring connector first to the positive battery terminal,
then connect the BLACK NEGATIV clamp / ring connector to the negative
battery terminal or vehicle chassis.
220VAC,50- 60Hz, 0.8A
6VDC, 3.5A;
12VDC, 3.5A;
12VDC, 1A;
Temperature Controlled
8 steps, Full-automatic Charging Cycle
> 1V
IP54
All Types of 6V & 12V Lead-acid
Batteries, and 12V Lithium Ion Batteries
2-120Ah (6V), 2-120Ah (12V), Maintains
All Battery Sizes
Clamp Connectors, Ring Connectors
0℃ ~ +40℃
3