PREVENTATIVE MAINTENANCE
1.
Always store the lift table in a well protected area where it will not be exposed to inclement weather,
corrosive vapers, abrasive dust, or any other harmful elements. The lift table must be free of water,
snow, sand, and debris before using.
2.
Leave hydraulic hose in the carton until needed.
3.
Lubricate moving parts regularly with a general purpose grease. Inspect all lift arms, saddle base, and
cylinder assemblies.
4.
Use a mild soap solution to wash external surfaces of the lift table but avoid any moving hydraulic
components.
5.
Inspect the lift table before each use. Do not use the lift table if any component is cracked,
broken, bent, or leaks hydraulic fluid. Do not use the lift table if it has loose or missing hardware,
components, or has been modified in any way. Take corrective action prior to using.
6.
Do not attempt to make any hydraulic repairs unless you are a qualified hydraulic repair person that is
familiar with this equipment.
7.
For best results change hydraulic fluid once per year.
TROUBLESHOOTING
PROBLEM
● Application will not extend, move, or
respond to pressurized fluid
● Application responds to pressurized fluid
but system does not maintain pressure
● Application will not return fluid to pump
● Cylinder will not retract
● Application will not fully extend
● Unit will not lower
● Poor performance
● Unit still does not operate
POSSIBLE CAUSE
● Overload condition
● Release valve not closed
● Overload condition
● Release valve not closed
● Hydraulic unit malfunction
● Malfunctioning coupler
● Resevoir overfilled
● Fluid level low
● Safety latches are in use
● Air trapped in system
Page 5
CORRECTIVE ACTION
● Remedy overload condition
● Ensure release valve is closed
● Remedy overload condition
● Ensure release valve is closed
● Secure load by other means. Open release valve,
depressurize pump and hose, remove coupler and replace
● Secure load by other means. Open relase valve,
depressurize pump and hose, and drain fluid to proper level
● Secure load, depressurize pump, and ensure proper fluid
level
● Lower safety latches
● Allow pressurized reservoir air to escape
● Contact an AFF authorized repair depot