Dyna-Form Mercury Advance Gebruikershandleiding - Pagina 10

Blader online of download pdf Gebruikershandleiding voor {categorie_naam} Dyna-Form Mercury Advance. Dyna-Form Mercury Advance 12 pagina's. Pressure relieving mattress suitable for use with patients at very high risk of pressure ulcer damage

9. Technical Data

9.1 Control Unit
Serial Number ................... As per label on rear of Control Unit
Electrical Supply. .............................. 220 – 240 volts, 50 Hz
Power Consumption ...............................................10 watts
Fuses ................................................................TA1H 250V
Protection against shock ...........................................Class 2
Noise Level ...............................................Approx. 30 dB (A)
Dimensions ...........................................245 x 160 x 95 mm
Weight...................................................................... 1.7 kg
Service Interval ............................... 12 months / 8760 hours
Expected life ............................................................5 years
Shelf life of parts ......................................................5 years
9.2 Mattress
Serial Number .....................Label on inside of mattress cover
Number of Air Cells ................ 14 Air Cells / 1 Static Foam Cell
Dimensions ......................... 1980 x 880 x 150mm (Nominal)
Weight.....................................................................13.4kg
Expected life of Mattress ...........................................5 years
Shelf life of Mattress parts .........................................5 years
10. Optimum Conditions
(Applies to Mattress and Control Unit)
10.1 Environment Conditions for Use
Transport .................................................... -25˚C – +70˚C
Storage ...................................................... -25˚C – +70˚C
Usage ......................................................... +5˚C – +40˚C
Humidity .......................................................... 10% – 93%
Atmospheric Pressure ........................... 700hPa – 1060hPa
Operational Altitude .............................................. ≤ 2000m
10.2 Exposure
Exposure to direct sunlight, dust, lint and general debris is not
considered to be an issue with the Mercury Advance System.
1 0
D Y N A - F O R M M E R C U R Y A D V A N C E
11. Symbols Guide
254 KG / 40 STONES
254 KG / 40 STONES
254 KG / 40 STONES
General Symbols
Control Unit Symbols
D I R E C T H E A L T H C A R E S E R V I C E S . C O . U K
Mattress Symbols
WASH AT 80˚
TUMBLE DRY ON LOW
WASH AT 80˚
TUMBLE DRY ON LOW
WASH AT 80˚
TUMBLE DRY ON LOW
0843
REFER TO
USER MANUAL
0843
0843
REFER TO
REFER TO
USER MANUAL
USER MANUAL
DO NOT BLEACH
DO NOT IRON
DO NOT BLEACH
DO NOT IRON
DO NOT BLEACH
DO NOT IRON
MAXIMUM USER
DO NOT USE
WEIGHT LIMIT
SHARP INSTRUMENTS
MAXIMUM USER
DO NOT USE
MAXIMUM USER
DO NOT USE
WEIGHT LIMIT
SHARP INSTRUMENTS
WARNING
WEIGHT LIMIT
SHARP INSTRUMENTS
THIS IS A STATEMENT THAT
WARNING
ALERTS THE USER TO THE
WARNING
POSSIBILITY OF SERIOUS INJURY
THIS IS A STATEMENT THAT
OR OTHERWISE ADVERSE
THIS IS A STATEMENT THAT
ALERTS THE USER TO THE
REACTIONS WITH THE USE
ALERTS THE USER TO THE
POSSIBILITY OF SERIOUS INJURY
OR MISUSE OF THE DEVICE
POSSIBILITY OF SERIOUS INJURY
OR OTHERWISE ADVERSE
OR OTHERWISE ADVERSE
REACTIONS WITH THE USE
REACTIONS WITH THE USE
OR MISUSE OF THE DEVICE
OR MISUSE OF THE DEVICE
CAUTION
PROTECT FROM HEAT
AND RADIOACTIVE SOURCES
CAUTION
PROTECT FROM HEAT
CAUTION
PROTECT FROM HEAT
AND RADIOACTIVE SOURCES
AND RADIOACTIVE SOURCES
HUMIDITY
ATMOSPHERIC PRESSURE
LIMITATION
LIMITATION
HUMIDITY
ATMOSPHERIC PRESSURE
HUMIDITY
ATMOSPHERIC PRESSURE
LIMITATION
LIMITATION
LIMITATION
LIMITATION
SERVICE
REFER TO
REQUIRED
USER MANUAL
SERVICE
REFER TO
SERVICE
REFER TO
REQUIRED
USER MANUAL
REQUIRED
USER MANUAL
DOUBLE INSULATED
CLASS II
DOUBLE INSULATED
DOUBLE INSULATED
CLASS II
CLASS II
IP: INGRESS PROTECTION
2: PROTECTION AGAINST FINGERS OR
OTHER OBJECT NOT GREATER THAN
IP: INGRESS PROTECTION
80MM IN LENGTH AND 12MM IN DIAMETER
IP: INGRESS PROTECTION
2: PROTECTION AGAINST FINGERS OR
1: PROTECTION FROM VERTICALLY
2: PROTECTION AGAINST FINGERS OR
OTHER OBJECT NOT GREATER THAN
DRIPPING WATER
OTHER OBJECT NOT GREATER THAN
80MM IN LENGTH AND 12MM IN DIAMETER
80MM IN LENGTH AND 12MM IN DIAMETER
1: PROTECTION FROM VERTICALLY
1: PROTECTION FROM VERTICALLY
DRIPPING WATER
DRIPPING WATER
DO NOT DRY CLEAN
DO NOT DRY CLEAN
DO NOT DRY CLEAN
TYPE BF
APPLIED PART
TYPE BF
TYPE BF
APPLIED PART
APPLIED PART
NO SMOKING
NO SMOKING
NO SMOKING
DO NOT USE
PHENOL
DO NOT USE
DO NOT USE
PHENOL
CAUTION
PHENOL
THIS IS A STATEMENT THAT
CAUTION
ALERTS THE USER TO THE
CAUTION
POSSIBILITY OF A PROBLEM
THIS IS A STATEMENT THAT
WITH THE SYSTEM ASSOCIATED
THIS IS A STATEMENT THAT
ALERTS THE USER TO THE
WITH ITS USE OR MISUSE
ALERTS THE USER TO THE
POSSIBILITY OF A PROBLEM
POSSIBILITY OF A PROBLEM
WITH THE SYSTEM ASSOCIATED
WITH THE SYSTEM ASSOCIATED
WITH ITS USE OR MISUSE
WITH ITS USE OR MISUSE
TEMPERATURE
LIMITATION
TEMPERATURE
TEMPERATURE
LIMITATION
LIMITATION
DO NOT DISPOSE OF
WITH HOUSEHOLD WASTE.
PLEASE REFER TO DHS WEBSITE
DO NOT DISPOSE OF
DO NOT DISPOSE OF
WITH HOUSEHOLD WASTE.
WITH HOUSEHOLD WASTE.
PLEASE REFER TO DHS WEBSITE
PLEASE REFER TO DHS WEBSITE
0843
0843
0843