4

4 Technical Specifications

• Direct connection from Battery and Input to HHO CELL generator, without external relays;
• 60A Max Power supply;
• LCD Module Monochrome Display Screen: Voltmeter + Ammeter + Cell Charge information;
• Automatic detection of battery voltage and auto configuration for: +12V/+24V power supply;
• Quad operational chip sensor with 1% tolerance Zenner voltage detector;
• Auto power ON when the Engine is running;
• 3 Seconds delay PWM control, after Engine ON is detected;
• Auto Power OFF when Engine is turned OFF;
• Soft PWM startup to the max Ampere out power supply;
• Embedded trimmer for PWM control: from 0% to 100% HHO CELL power supply;
• Logical IC sensor, MUST be powered with 2 wires DIRECT from the battery;
• Embedded 3 way power barrier: Positive, Ground, Negative from Cell (CELL – OUT);
• Optional Water tank sensor switch embedded on system;
• Frequency: 36kHz
HHO Plus, Alternative Energies, Lta – Travessa das Serras 33, Vieira de Leiria, Portugal – Tel. 00351244697116 – Email: [email protected]