Gage Bilt GB108A/2 Originele handleiding - Pagina 9
Blader online of download pdf Originele handleiding voor {categorie_naam} Gage Bilt GB108A/2. Gage Bilt GB108A/2 17 pagina's. 20v battery installation tool
Battery (VP1086):
Always make removing the battery (VP1086) from the installation tool your first step before making adjustments, changing parts or
overhauling and installing the battery (VP1086) into the tool your last step before using to prevent accidental starting of the tool.
2.
The battery (VP1086) has a latch on the front side. To insert or remove the battery, press the latch downwards and push the
battery (VP1086) into the installation tool foot or pull it out.
3.
Use the battery (VP1086) in the installation tool only in the specified temperature range 23°F - 113°F (-5°C - 45°C).
4.
Charge the battery (VP1086) only in a temperature range between 32°F - 104°F (0°C - 40°C).
5.
Use only an approved charger.
6.
Never short-circuit the battery (VP1086).
7.
If the battery (VP1086) shows signs of visible damage, no not use it any longer and dispose of it in a proper manner.
8.
Keep the battery (VP1086) away from moisture and liquids.
Preparing the Installation Tool (GB108A):
Attach the mandrel collection bottle (VP1002) by turning to the right.
Note: Tool will not function without mandrel collection bottle (VP1002) or cover cap (VP1321)
attached. (See safety switch below).
2.
Apply blue Loctite® #242 to threads of piston on tool and on male threads of collet adapter (110749).
Thread collet adapter (110749) onto piston of tool and tighten. Thread adapter anvil (110750)
to tool and tighten using wrench flats provided.
Select proper nose assembly (Contact Gage Bilt for more information). Screw nose assembly
onto adapter (108751). Follow instructions on nose assy data sheet.
Push the battery (VP1086) into the foot of the installation tool from the front and ensure it is properly engaged.
Safety Switch:
This installation tool is equipped with a safety switch in the rear of installation tool and thus conforms to the Machinery Directive.
This prevents the installation tool from being used without the mandrel collection bottle (VP1002) or cover cap (VP1321).
2.
Never bypass the safety switch.
3.
Never operate the tool without the mandrel collection bottle (VP1002) or cover cap (VP1321).
If you have to work in confined spaces, the cover cap (VP1321) can be used instead of the mandrel collection bottle (VP1002).
When working with the cover cap (VP1321), hold the installation tool with the anvil insert facing downwards after each set fastener
to ensure that the sheared mandrel drops out of the tool to the front.
Do not use cover cap (VP1321) with non-self releasing nose assemblies. This would result in damage to the installation tool.
GB108A 20V BATTERY INSTALLATION TOOL
HOW TO SET-UP THE GB108A cont.
Safety Switch
#
Cover Cap (VP1321)
Images may not reflect actual tool
8/21