Great Canadian Systems IQ-D Bedieningshandleiding - Pagina 6
Blader online of download pdf Bedieningshandleiding voor {categorie_naam} Great Canadian Systems IQ-D. Great Canadian Systems IQ-D 12 pagina's. Newco iq2000p: operation manual
Service Options and Troubleshooting
Message
Fill Tank Press Brw1
Cycles Since Service
Total Cycles
Error Messages
Fill Tank Press Brw1
Cycles Since Service
00150
value set in Service Cycles as outlined above. To clear the number press and hold both the "-" and "+" keys
simultaneously until the number is cleared (approximately 5 seconds).
Total cycles
01140
Error Messages
message is cleared (approximately 5 seconds). Error messages and their description are noted below.
Error Messages and Troubleshooting
CAUTION:
Disconnect power to brewer before servicing.
* Call For Service *
present. Error Messages are outlined below. Use the procedures outlined in the previous section to display the
error. In all cases which produce one of the outlined errors the brewer will be disabled until the condition is
corrected and the error is reset. To clear the error message press and hold both the "-" and "+" keys
simultaneously until the message is cleared (approximately 5 seconds).
Error Messages
Err: Fill Probe
Check your water supply up to the brewer to see that you are receiving adequate flow. If yes shutoff water to the
brewer and loosen the cap on the inlet of the water solenoid. Check to see if there is debris blocking the opening.
If the water flow and valve appear to be normal it may be necessary to change the flow washer located internally in
the solenoid. In some instances because of Low Water Pressure we recommend increasing the size of the flow
washer to .75 or 1 gallon per minute to increase the flow rate to the brewer. If the hot water faucet is being used
Table 2 - Summary of Service Mode Options/Messages
Service Function/Message
Press BREW key to fill tank when
displayed. No maximum run time.
Depress '-' and '+' key to clear.
Information only. Can not change.
Depress '-' and '+' key to clear.
Err: Fill Probe
Err: Safety Probe
Err: Open Tmp Sensor
Err: Shrt Tmp Sensor
Err: Bad Heater Elem
Err: Faucet Timeout
This function is for the initial tank fill cycle as explained in the Brewer Fill Program
section on page 1. There is no maximum run time to fill the tank in this mode.
This is the number of brew cycles which the unit has seen since the message was
last cleared. If the "* Call For Service *" message appears and the brewer
continues to operate then the Cycles Since Service has reached or exceeded the
This number is the cumulative brewer cycles and can not be altered.
This area is for the display of error messages which have triggered the * Call For
Service * message and disabled the brewer from normal operation. To clear the
error message press and hold both the "-" and "+" keys simultaneously until the
This message will display under 2 conditions. Condition one occurs when the
Cycles Since Service has reached the programmed value for service cycles. The
brewer will continue to operate normally. Condition two occurs when an error is
This error occurs when the fill solenoid, in a normal brew, has exceeded the
maximum fill valve run time with out the water level in the tank making contact with
the water level probe. The problem usually is the result of poor water supply.
Use for initial setup to fill tank.
Displays the brew cycles since message was last
cleared.
Cumulative brewer cycles.
Cause:
Fill solenoid runs more than 5 consecutive min.
Water has fallen below heater safety probe.
Thermistor circuit break.
Thermistor circuit short.
Element heating time exceeded 30 minutes.
Faucet open for more than 4 consecutive min.
- 6 -
Description