The Power Beyond Port can connect to another valve for conveyor and clamp, or must go to the filter and tank. The
return hose can be #8 or 1/2" diameter for the first five feet. If a longer hose is required it must be #12 or 3/4" up to
thirty feet. If the total return hose length is greater than thirty three feet #16 or 1" hose should be used. The filter
must be rated for 15 GPM plus any additional pump flowing into it. The saw motor should run between 4000 RPM
and 5500 RPM. At this speed the pressure at the return to filter connection should not exceed 80 psi when the saw
motor is running. We do not recommend using quick disconnects but if you choose to use quick disconnects in the
tank line, first consult the manufacture to determine the correct size to keep the back pressure low enough in cold
temperatures. Failure to properly size the hose and filter or properly connect the return hose to a filter and tank will
shorten the motor shaft seal life and will not be covered by warranty.

Chain Tension and Sharpening

Figure 5 shows the chain tensioning screw. A #2 or #3 Phillips screwdriver is required to turn the tension screw. With
the supplied saw bar, correct tension is when the cutters come off the rails roughly 1/8" with a tug of finger
pressure. Refer to the Oregon Mechanical Timber Harvesting Handbook for more tensioning information and
sharpening information.
Fig. 5
7