Hi-Force TLE5014 Gebruiksaanwijzing - Pagina 14

Blader online of download pdf Gebruiksaanwijzing voor {categorie_naam} Hi-Force TLE5014. Hi-Force TLE5014 18 pagina's.

Carry out basic maintenance on a regular basis to keep the jacking system operating in a trouble-free
manner. Maintenance intervals are determined by the frequency of use of the system and the operating
conditions on site.
Keep the unit clean. Particularly the saddle and load-lock/ slip-lock extension pieces (if used).
All saddle receiver holes should be blown out with compressed air. Then lightly lubricate the saddle
pins and saddle receiver holes. Lubricate the handle positioning latch pins and holes (18).
The oil level in the reservoir should not be allowed to drop below the centre of the top oil level
indicator sight-glass (16). (Cylinder fully retracted)
ALWAYS check the oil level with the lifting cylinder in the fully retracted position to ensure the correct
oil level is displayed. Keep the oil reservoir topped-up with high grade ISO46 hydraulic oil as per
section 5.2.
Oil should be replaced after approximately 500 working hours, or more frequently in dusty
conditions. To replace the oil, disconnect from the mains power supply, remove the oil drain plug
(14) on the bottom of the reservoir and drain the used oil into a suitable container. Replace the oil
drain plug (14) and refill with high grade ISO46 hydraulic oil as per section 5.2. Bleed trapped air
from the system if necessary (See section 5.3).
IMPORTANT:

8.0 Maintenance and Storage

If the oil level does fall below the lower oil level indicator (at any time), air could
be drawn into the pump, causing erratic operation and possible damage. To top
up hydraulic oil, remove the top cover (12) and fill via the orange filler breather
cap (19). (See Section 5.2).
ALWAYS dispose of used hydraulic oil in a responsible manner, in accordance with
local regulations.
Operating Instruction Manual:
OM-TLE50-01
14
From Serial Number:
All