7
FAULT DIAGNOSTICS
7.1
Switch logic S1-S4
S3
The 4 limit switches are connected to the electronics module via two
connectors X5 and X6.
The limit switches are break contacts, i.e. when the appropriate
position is reached, the electric signal is "0".
If there is a line break or if a connector is not plugged in, the input
signals are also "0".
142_58300000122107_ara_en_b.doc – 02.02.09
S2
S1
S4
S1
S2
S3
lower
grill
upper
end
position
end
0
0
1
1
0
0
0
1
0
0
0
1
S4
Lifting motor and fan
crush
output
protection
Lifting motor runs to
1
upper end
Lifting motor and
0
fan motor do not run
Basic setting is running,
Fan can be switched
0
to any setting
Lifting motor does not
run
Lifting motor and
0
fan motor do not run
Seite 14 von 16