Gaggenau VG 264 220 AU Gebruiksaanwijzing - Pagina 8
Blader online of download pdf Gebruiksaanwijzing voor {categorie_naam} Gaggenau VG 264 220 AU. Gaggenau VG 264 220 AU 16 pagina's.
Operating the appliance
en
Individual parts of the burners
Ensure that the burner parts are fitted in the correct
position and are straight; otherwise, there may be
ignition problems or problems during operation. The
lugs must engage in the relevant recesses.
( Burner cap
0 Burner head
8 Ignition plug
@ Thermocouple element for flame monitoring
8
Operating the appliance
N otes
O p e r a t i n g t h e a p p l i a n c e
–
Only use the accessories specified. Do not line the
stainless steel recess (e.g. with aluminium foil).
–
Do not cover the ventilation openings on the back
of the control panel.
–
The burner and ignition plug must be clean and dry.
–
Only light the burners if the pan supports and all
burner parts are correctly fitted.
–
To ignite a burner, firmly press the control knob
down as far as possible and hold it there, then turn
it to the required position.
–
Once ignited, press and hold the control knob for
approx. 2 to 4 seconds to enable the heat sensor
that opens the gas flow to heat up first.
–
If the flame does not ignite within 2 to 4 seconds,
turn the control knob anti-clockwise to the lowest
setting and, once ignited, turn it back to the highest
setting. It can often be quicker to ignite the burner
in the lowest setting because different gases have
different ignition characteristics.
–
When one burner is ignited, an ignition spark will
also be generated at all the other burners.
–
Do not touch the ignition plug while the gas
appliance is being lit.
–
It is important to keep the appliance clean. If the
ignition plugs are dirty, this may cause ignition
problems. Clean the ignition plugs regularly with a
small, non-metallic brush. Take care to prevent the
ignition plugs from suffering any heavy knocks.
Abnormal operation
Flames are usually blue and sharply defined. If the
flames are yellowish or noisy or if the gas does not
ignite within the period specified under "switching on"
abnormal operation is indicated. Refer to chapter "After-
sales service" of this manual for service contact details.