ADEMCO Ademco VISTA-20P Handleiding voor programmering - Pagina 4

Blader online of download pdf Handleiding voor programmering voor {categorie_naam} ADEMCO Ademco VISTA-20P. ADEMCO Ademco VISTA-20P 17 pagina's. Programming auto arming and disarming schedules
Ook voor ADEMCO Ademco VISTA-20P: Snelle installatiehandleiding (2 pagina's), Handleiding voor programmering (17 pagina's), Gebruikershandleiding (20 pagina's), Snelstarthandleiding (6 pagina's), Snelle installatiehandleiding (2 pagina's), Snelle installatiehandleiding (2 pagina's), Handleiding voor programmering (2 pagina's), Beknopte handleiding (2 pagina's)

ADEMCO Ademco VISTA-20P Handleiding voor programmering
NOTE: Entry of a number other than one specified will give unpredictable results.
For fields *43- *46: Enter 0–9; #+11 for B; #+12 for C; #+13 for D; #+14 for E; [#+15 for F]. Enter [ ✱ ] as the fourth digit if a 3-digit account number (for 3+1 dialer
reporting format) is used. Enter 0 as the first digit of a 4-digit account number for Nos. 0000-0999. Exit field by pressing ✱ (and press next field number) if only 3
digits are used. E.g., For Acct. B234, enter: #+11| 2 | 3 | 4
43 PARTITION 1 PRIMARY SUBS. ACCT. No.
44 PARTITION 1 SECONDARY SUBS. ACCT. No.
45 PARTITION 2 PRIMARY SUBS. ACCT. No.
46 PARTITION 2 SECONDARY SUBS. ACCT. No.
PHONE SYSTEM SELECT
47
48
REPORT FORMAT
49
SPLIT/DUAL REPORTING
50
15 SEC DIALER DELAY (BURG)
✱ 53
SECOA/RADIONICS SELECT
✱ 54
DYNAMIC SIGNALING DELAY
✱ 55
DYNAMIC SIGNALING PRIORITY
TO PROGRAM SYSTEM STATUS, & RESTORE REPORT CODES ( ✱ 59 – ✱ 76, & ✱ 89):
For 3+1 or 4+1 Standard Format: Enter a code in the first box: 1–9, #+10 for 0, #+11 for B, #+12 for C, #+13 for D, #+14 for E, #+15 for F.
A 0 ( not #+10) in the first box will disable a report. A 0 ( not #+10) in the second box will result in automatic advance to the next field.
For Expanded or 4+2 Format: Enter codes in both boxes (1st and 2nd digits) for 1–9, 0, or B–F, as described above.
A 0 ( not #+10) in the second box will eliminate the expanded message for that report. A 0 ( not #+10) in both boxes will disable the report.
For Ademco Contact ID® Reporting: Enter any digit (other than 0) in the first box, to enable zone to report (entries in the second boxes are ignored).
A 0 ( not #+10) in the first box disables the report.
SYSTEM STATUS REPORT CODES ( ✱ 59– ✱ 68)
✱ 59
EXIT ERROR REPORT CODE
✱ 60
TROUBLE REPORT CODE
✱ 61
BYPASS REPORT CODE
✱ 62
AC LOSS REPORT CODE
✱ 63
LOW BAT REPORT CODE
✱ 64
TEST REPORT CODE
✱ 65
OPEN REPORT CODE
✱ 66
ARM AWAY/STAY RPT CODE
| | |
| | |
|
|
|
|
[1]
primary
[0]
[0]
[0]
UL: see installation instructions for requirements
[0]
See box above.
|
[00]
See box above.
|
[00]
See box above.
|
[00]
See box above.
|
[00]
See box above.
|
[00]
See box above. Use Scheduling mode to set periodic test reports.
[0,0,0]
Part. 1 Part. 2 Common
Away Stay
Away Stay
Part. 1
Part. 2
– 4 –
See box above for entries. To clear entries
[FFFF]
from field, press * 43 *.
See box above for entries. To clear entries
[FFFF]
from field, press * 44 * .
See box above for entries. To clear entries
|
[FFFF]
from field, press * 45 * .
See box above for entries. To clear entries
|
[FFFF]
from field, press * 46 * .
If Cent. Sta. IS NOT on a WATS line:
0=Pulse Dial; 1=Tone Dial;
if Cent. Sta. IS on a WATS line:
2 = Pulse Dial ; 3 = Tone Dial
0 = 3+1, 4+1 ADEMCO L/S STANDARD
[70]
1 = 3+1, 4+1 RADIONICS STANDARD
secondary
2 = 4+2 ADEMCO L/S STANDARD
3 = 4+2 RADIONICS STANDARD
6 = 4+2 ADEMCO EXPRESS
7 = ADEMCO CONTACT ID® REPORTING
8 = 3+1, 4+1 ADEMCO L/S EXPANDED
9 = 3+1, 4+1 RADIONICS EXPANDED
0 = Disable (Backup report only)
Primary Phone No.
Phone No.
1 = Alarms, Restore, Cancel
2 = All except Open/Close, Test Open/Close,
3 = Alarms, Restore, Cancel
4 = All except Open/Close, Test All
5 = All
0 = no UL: must be "0"; 1 = yes
0 = Radionics (0-9, B-F)
1 = SESCOA (0-9 only reporting)
Select "0" for all other formats.
Delay selectable from 0 to 225 secs in 15-sec
[0]
increments.
0 = no delay (both signals sent), 1 = 15 secs,
2 = 30 secs, etc. UL: must be "0"
0 = Primary Dialer first; 1 = Long Range Radio
[0]
first.
See box above.
[0,0,0,0,0,0] See box above.
Away Stay
Common
Second
Others
Test
All
All