Variant A: Flat extractor hood with flue cover
Variant B: Sloped extractor hood with flue cover
Variant A: Flat extractor hood without flue cover
Variant B: Sloped extractor hood without flue cover
Installing the appliance bracket
Screw on the appliance bracket for the extractor
1.
hood hand-tight.
18
Use a spirit level to align the appliance bracket hori-
2.
zontally and screw it firmly in place.
Installing the appliance
Remove the protective film from the rear.
1.
Once the appliance is installed, fully remove the
protective film.
Hook the appliance into the appliance bracket in
2.
such a way that it clicks firmly into place.
To align the appliance, slide the appliance to the
3.
right or to the left as required.
Tighten the safety screws.
4.
When you install a flue cover, install the bracket and
hold it in place while screwing it in tight.
Piping
Air extraction mode
¡ If you operate the appliance in air extraction mode,
a flue cover must be installed.
Circulating-air mode
¡ If you operate the appliance in circulating-air mode,
the enclosed odour filters must be installed.
¡ For operation in circulating-air mode, the installation
of the flue cover is optional.
Note: If you are using an aluminium pipe, smooth the
connection area beforehand.
We recommend the piping with an exhaust air pipe dia-
meter of 150 mm.
Establishing the exhaust air connection (exhaust
pipe, 150 mm diameter)
Secure the exhaust pipe to the air pipe connector.
1.
Establish the connection to the exhaust air opening.
2.
Seal the joints.
3.
Establishing the exhaust air connection (exhaust
pipe, 120 mm diameter)
Secure the reducing connector to the air-pipe con-
1.
nector.