GS-46 ENVIRONMENTAL QUALIFICATION FORM

APPLICABLE SPECIFICATIONS: RTCA DO-227, RTCA DO-204, RTCA DO-160C
ENVIROMENTAL CATEGORY: 227/227/227/227/204/204/XXXXXXXXXXXXXXXX
TEST CONDITIONS
Survival Low / High Temperature Cycle
Altitude
Decompression
Humidity
Shock
Vibration
Explosion Proofness
Waterproofness
Fluids Susceptibility
Sand and Dust
Fungus Resistance
Salt Spray
Magnetic Effect
Power Input
Voltage Spike
Audio Freq. Conducted Susceptibility
Induced Signal Susceptibility
R.F. Susceptibility
Emission of R.F. Energy
Lightning Induced Transient Susceptibility.
Lightning Direct Effects
Icing

EBC-406HM ENVIRONMENTAL QUALIFICATION FORM

Nomenclature: 406 / 121.5 / 243.0MHz Emergency Locator Transmitter.
Part Numbers: EBC-406HM, BB-12M, GS-46 TSO Number: C126
Other Applicable Specifications: RTCA DO-204
Manufacturer: Emergency Beacon Corporation Address: 15 River Street, New Rochelle, New York
Revision of DO-160: C and D
Tests started: 5/20/06. Tests completed: 2/25/07.
ENVIRONMENTAL CATEGORIES: D1XBC(204)(204)XRFXXSXXXXZ(204)X(A1C1)XXA
CONDITIONS
TEMPERATURE AND ALTITUDE
OPERATING LOW TEMPERATURE
OPERATING HIGH TEMPERATURE
IN-FLIGHT LOSS OF COOLING
ALTITUDE
DECOMPRESSION
OVERPRESSURE
TEMPERATURE VARIATION
HUMIDITY
OPERATIONAL SHOCK
OPERATIONAL CRASH SAFETY
VIBRATION
EXPLOSION
WATERPROOFNESS
FLUIDS SUSCEPTIBILITY (salt water)
SAND AND DUST
FUNGUS
SALT SPRAY
MAGNETIC EFFECT
POWER INPUT
VOLTAGE SPIKE
AUDIO FREQUENCY SUSCEPTIBILITY
INDUCED SIGNAL SUSCEPTIBILITY
RADIO FREQUENCY SUSCEPTIBILITY
RADIO FREQUENCY EMISSION
LIGHTNING INDUCED TRANSIENT SUSCEPTIBILITY
LIGHTNING DIRECT EFFECTS
ICING
ELECTROSTATIC DISCHARGE
OTHER DO-204 ENVIRONMENTAL TESTS PASSED
CONDITIONS
IMPACT PENETRATION
CRUSH
FLAME
POST CRASH IMMERSION
OTHER ELECTRONIC TESTS
LONG TERM FREQENCY DRIFT
* Not tested but identified as meeting requirement from manufacturer's specifications.
July 2022, Rev 8
EMERGENCY BEACON CORPORATION
Section
DO-160C
SECTION
4.0
4.5.1
4.5.2 & 4.5.3
4.5.4
4.6.1
4.6.2
4.6.3
5.0
6.0
7.0
7.0
8.0
9.0
10.0
11.0
12.0
13.0
14.0
15.0
16.0
17.0
18.0
19.0
20.0
21.0
22.0
23.0
24.0
25.0 (DO-160D)
SECTION
DESCRIPTION OF TESTS CONDUCTED
2.3.4.2
55 LBS IMPACT FROM 6 INCHES TEST
2.3.4.3
1000 LBS APPLIED FORCE CRUSH TEST
2.3.7.1
15 SECOND FLAME EXPOSURE TEST
2.3.9.4
1 METER SALT WATER IMMERSION TEST
2.3.2 THRU 2.3.2.6
LOW-TEMP. LIFE, HIGH TEMP., TEMP. GRADIENT/ FREQ. STABILITY, VSWR THERMAL SHOCK, SELF TEST
2.4.2.1.4
IDENTIFIED AS PER RF OSC. MFG. DATA*
Paragraph
-
2.3.3
-
2.3.4
-
2.3.5
-
2.3.6
-
2.3.4.1
8.0
2.3.5
9.0
-
10.0
-
11.0
-
12.0
-
13.0
-
14.2
-
15.0
-
16.0
-
17.0
-
18.0
-
19.0
-
20.0
-
21.0
-
22.0
-
23.0
-
24.0
-
DESCRIPTION OF TESTS CONDUCTED
EQUIPMENT TESTED TO CATEGORY D1
EQUIPMENT TESTED TO CATEGORY D1
EQUIPMENT TESTED TO CATEGORY D1
NOT APPLICABLE
EQUIPMENT TESTED TO CATEGORY D1
EQUIPMENT TESTED TO CATEGORY D1
EQUIPMENT TESTED TO 170 kPa abs.
EQUIPMENT TESTED TO CATEGORY B
EQUIPMENT TESTED TO CATEGORY C
EQUIPMENT TESTED TO CATEGORY (204)
EQUIPMENT TESTED TO CATEGORY (204)
EQUIPMENT TESTED TO CATEGORY (204)
NOT APPLICABLE
EQUIPMENT TESTED TO CATEGORY R
EQUIPMENT TESTED TO CATEGORY F
NOT APPLICABLE
NOT APPLICABLE
EQUIPMENT TESTED TO CATEGORY S
NOT APPLICABLE
NOT APPLICABLE
NOT APPLICABLE
NOT APPLICABLE
EQUIPMENT TESTED TO CATEGORY Z
EQUIPMENT TESTED TO CATEGORY (204)
NOT APPLICABLE
EQUIPMENT TESTED TO CATEGORY A1C1
NOT APPLICABLE
NOT APPLICABLE
EQUIPMENT TESTED TO CATEGORY A
8
Category
Per DO-227
Per DO-227
Per DO-227
Per DO-227
Per DO-204
Per DO-160C/204
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X