HP- 100 / 120
! 
●Be sure to unplug the pump unit. 
●Replace the diaphragms and the valves with new ones at least once a year to one and a 
half year regularly in order to maintain their initial performance. 
●For chamber block replacement, be sure to change both chamber blocks at the same time. 
●The rod employs powerful permanent magnets. Therefore, be sure to remove your watch 
and  any  other  precision  machines  before  operation  as  they  may  be  affected  by  the 
strong magnetic force. 
●Do not put the actuating rod close to a magnetic card, magnetic disk or other magnetic 
media as the data may be destroyed.
STEP
STEP
REMOVAL OF THE CHAMBER BLOCKS
1
1
To remove the upper housing. 
(Refer to
Remove the sound absorber.
STEP
STEP
2
2
Uudo  the  frame  screws  and  remove  the  frame 
cover.
STEP
STEP
3
3
Pull out the L-tube from the casing block.
2
AUTION
REMOVING UPPER HOUSING
REPLACING THE CHAMBER BLOCK