HIBLOW hp-120 Handmatig - Pagina 9

Blader online of download pdf Handmatig voor {categorie_naam} HIBLOW hp-120. HIBLOW hp-120 9 pagina's.
Ook voor HIBLOW hp-120: Gebruiksaanwijzing (13 pagina's)

HIBLOW hp-120 Handmatig
HP- 100 / 120
STEP
STEP
FITTING THE ELECTROMAGNET
4
4
Mount new the electromagnets in the unit. 
Tighten up nuts with nut driver.
STEP
STEP
5
5
Install the SP switch to the frame with the screws. 
●Be careful of the direction of switch lever. (Refer to the 
pictures)
STEP
STEP
6
6
Insert the wire into the silicon tube, and tie up in a 
bundle. 
Strip the coating off each wire. 
(5-7mm from the end) 
Connect the wires to the terminals. 
Solder the wires to the terminals. 
The wire requires a soldered connection.
STEP
STEP
7
7
This  completes  the  electromagnet  replacement 
procedure.
REPLACING THE ELECTROMAGNET
9