P
. 42004-699L2D
UB
14 of 14
M
709-901 S
S
H
/S
A
P
ODEL
MART
ERIES
ANDSET
PEAKER
MPLIFIER
AGE
Specifications
Electrical
Supply voltage ....................................................................... 90 to 140 V ac (120 V ac nominal), 50/60 Hz
Power consumed @ nominal ac ........... Zero/maximum signal (12 watts): 15 VA, 9 watts/59 VA, 32 watts
Speaker Amplifier
Output ............................................................................... 12 watts minimum, with nominal supply voltage
Frequency response ....................................................................... 350 to 6,500 Hz, +0/−3 dB, ref. to 1 kHz
Distortion ......................................................................................... 1% maximum THD @ 1 kHz, 12 watts
SmartVolume™
Monitor range (low gain) ................................................................................................... 62 to 100 dB SPL
Offset (above ambient) User Level Adjustment ........................................................................... 0 to 48 dB
Minimum User Level Adjustment ............................................................................. Off; 85 to 125 dB SPL
Handset Amplifier
Output ................................................................................................... 1.5 V
nominal into 33-ohm load
RMS
Frequency response with 5 mV
input (AGC on) ...................... 350 to 6,500 Hz, +0/−3 dB ref. to 1 kHz
RMS
Distortion ..................................................................................................... 1.5% maximum THD @ 1 kHz
Mechanical
Dimensions ...................................... 7.69 H 6.75 W 3.57 D inches (195.3 171.4 90.7 mm), overall
Environmental
Temperature range ......................................... −22° F to +158° F (−30° C to +70° C), operating and storage
Humidity ...................................................................................................................... 95%, non-condensing
Approvals
NRTL listed ................................................................................................. Class I, Div. 1, Groups B, C, D;
(USA and Canada)
Class II, Div. 1, Groups F, G;
Class III, Div. 1
when used with listed Model 7085-004-UL, 708-001-UL, 7085-001-UL
7085-005-UL, or 707-001-UL Enclosure
CE Mark
f:\standard ioms - current release\42004 instr. manuals\42004-699l2d.doc