HID Signo 40K Installatiehandleiding
Blader online of download pdf Installatiehandleiding voor {categorie_naam} HID Signo 40K. HID Signo 40K 2 pagina's. 13.56 mhz/125 khz/2.4 ghz contactless and keypad readers
Ook voor HID Signo 40K: Beknopte handleiding (3 pagina's)
INSTALLATION GUIDE
HID Signo
Reader
™
13.56 MHz / 125 kHz / 2.4 GHz Contactless and Keypad Readers
SRD Models: 20, 20K, 40, 40K
www.hidglobal.com/PLT-03704
Scan the QR code or visit the link to see
the multi-language electronic version of
this document.
Lisez le code QR ou suivez le lien pour
consulter la version française de ce
document.
Escanee el código QR o visite el vínculo
para consultar la versión en Español de
este documento.
Scannen Sie den QR-Code oder öffnen Sie
den Link für die deutsche Version dieses
Dokuments.
Supplied parts
HID Signo Reader (1)
Installation Guide (1)
Flat head/countersunk 0.138-20 x 1.5" self–
tapping screws (2) – for installing the reader
directly to a wall (no junction box)
Flat head/countersunk 0.138-32 x 0.375"
machine screws (3) – for Imperial (US)
junction box installation (2) and attaching
the reader to the mounting plate (1)
Recommended parts (not supplied)
Cable, 5-10 conductor (Wiegand or
Clock-and-Data), 4 conductor Twisted Pair
Over-All Shield and UL approved, Belden
3107A or equivalent (OSDP)
Certified LPS DC power supply
Metal or plastic junction box
Security tool HID 04-0001-03 (for
anti-tamper screw)
© 2019 – 2020 HID Global Corporation/ASSA ABLOY AB. All
rights reserved. HID, the HID Brick logo, the Chain Design, HID
Signo, HID Reader Manager, iCLASS, and HID Mobile Access are
trademarks or registered trademarks of HID Global, ASSA ABLOY
AB, or its affiliate(s) in the US and other countries and may not be
used without permission. All other trademarks, service marks, and
product or service names are trademarks or registered trademarks
of their respective owners.
Optional features
Tamper – Enabled by default and activated when the mounting plate is removed. The tamper is
normally closed and changes to open circuit between Tamper 1 and Tamper 2 control lines. Tamper
1 and Tamper 2 control lines are interchangeable. Either of these lines can be connected with the
reader ground line to reduce the number of cable cores required in the reader cable. Tamper 1 and
Tamper 2 are rated 0–12VDC at 100mA.
Hold Input – When asserted, this line either buffers a card (default) or disables a card read until
released, as configured.
1
Mount the mounting plate
Observe precautions for handling
ELECTROSTATIC SENSITIVE DEVICES
hi dg l ob a l .com
PLT-03703, Rev. A.2
Faça a leitura do código QR ou acesse
o link da versão em português deste
documento.
Scansiona il codice QR o visita il link della
versione Italiana di questo documento.
Отсканируйте QR-код или пройдите по
ссылке, чтобы получить версию этого
документа на русском языке.
扫描 QR 码或访问此 文档的中文版本的链接。
この文書の日本語版を表示するには、 QR コードを
スキャンするか、 リンクを クリ ックします。
QR 코드를 스캔하거나 링크를 방문하면 이 문서의
한국어 버전을 볼 수 있습니다.
Flat head/countersunk M3.5 x 12mm machine
screws (2) – for Metric (EU etc) junction box
installation
Flat head/countersunk 0.138-32 x 0.375"
security screw (1) – alternative anti-tamper
screw for attaching the reader to the
mounting plate
5-pin terminal connectors, terminal strip
models only (2)
Drill with various bits for mounting hardware
Mounting hardware
Reader spacer when mounting on or near
metal or metal junction boxes. Refer to the
Reader and Credentials How to Order Guide
(PLT-02630) for available options and part
numbers)
Junction box
ATTENTION
CAUTION: Install the reader
on a flat, stable surface. Failure
to do so may compromise
the IP rating and/or tamper
feature. If mounting on
or near metal, a spacer is
recommended for optimal
read performance. Refer to the
Readers and Credentials How
to Order Guide (PLT-02630)
for available options and part
numbers.
CAUTION: Use the supplied
screws to ensure correct fitting
and to avoid damaging the
reader or mounting plate. HID
is not responsible for damage
due to use of unapproved
mounting hardware.
For Imperial (US):
Use supplied flat head/
countersunk 0.138-32 x 0.375"
screws.
For Metric (EU etc):
Use supplied flat head/
countersunk M3.5 x 12mm
screws.
2
Wire the reader
Pigtail versions
18"
(0.46m)
PIGTAIL
Red
Black
White
Green
Orange
Yellow
Blue
Brown
Violet/White
Violet
Bare
*Dependent upon reader configuration.
Note: Wiring the reader incorrectly may permanently damage the reader.
Note: Previous iCLASS® readers had reversed RS-485 wiring (P2-7 & P2-6 - A & B). When
upgrading to a HID Signo reader, ensure proper connections as defined above.
Note: Data 0 and Data 1 wires for Wiegand may be reused for OSDP. However, standard
Wiegand cable may not meet RS485 twisted pair recommendations.
Note: For OSDP cable lengths greater than 200 ft (61 m) or EMF interference, install 120Ω +/- 2Ω
resistor across RS-485 termination ends.
Note: For keypad configuration, with the keypad reader operating as 26 bit emulation, enter the
facility code followed by # within five seconds of power-up. The facility code must be entered as
three digits (i.e., for a facility code of 10 enter 0-1-0-#). If unsuccessful, the reader LED displays
solid red. Power-cycle the reader and retry entering the facility code.
HID Signo readers use facility codes between 1-255, and no default is set. Once a facility code
is entered, the reader LED displays violet, then solid red. Then, power-cycle the reader. If there
are two short beeps after entering a PIN, the reader facility code is not configured. In this case,
power-cycle the reader and retry entering the facility code.
3
Secure the reader to the mounting plate
1
2
4
Power and test the reader
Power the reader. The reader will
beep and the LED will flash.
An ASSA ABLOY Group brand
Terminal strip versions
TERMINAL
DESCRIPTION
1
+VDC
2
Ground (RTN)
3
Wiegand Data 1 / Clock / RS485-A*
4
Wiegand Data 0 / Data / RS485-B*
5
LED Input (GRN)
6
Beeper Input
7
Hold Input / LED Input (BLUE)*
8
LED Input (RED)
9
Tamper 2 (RLY2)
10
Tamper 1 (RLY1)
—
Drain (pigtail models only)
1. Hook the top of the reader on the top of
the mounting plate.
2. Align the bottom of the reader with the
bottom of the mounting plate.
3. Secure the reader to the mounting plate
using the supplied 0.138-32 x 0.375" screw.
Security/anti-tamper screw:
0.138-32 x 0.375" screw (supplied).
Non-security/standard screw:
0.138-32 x 0.375" screws (supplied).
3
Test the reader with a credential. The reader
will beep and the LED will flash.