Dynamatic 15-539-0015 Instructieblad - Pagina 8
Blader online of download pdf Instructieblad voor {categorie_naam} Dynamatic 15-539-0015. Dynamatic 15-539-0015 14 pagina's.
Mechanical Unit Model Numbers
AC/ACW/ACS/PD/VT
Fractional Hp (FHP)
Fractional Hp
181/182/184/186
214/216/254/256
280/320/360/440
Mechanical Unit Model Numbers
AC/ACW/ACS/PD/VT Fractional
Hp (FHP)
FHP/181/182
184/186/214
216/254/256/280
320/360/440
*Typical product number stamped on mechanical unit nameplate:
1. A1-100214-0053, specific mechanical model is AC-214
2. B2-100210-0008, specific mechanical model is AS-21
Trimpot Illustration:
3.
Torque Limit Mod PCB 15-444-2
a. Set the Torque Limit Damping potentiometer R18 at 50% CW
b. Set the Torque Limit potentiometer R19 at 50% CW (this setting is approximately 150% of
rated motor torque)
c. Set HI Damping potentiometer R20 to 0% (Full CCW)
8
AS/AT/AE/VT/EC
14/112/140
18/21/132/160/180/210
25/27/180/225/250/280
320/360/440
AS/AT/AE/VT/EC
14/18/112/132/140/180
21/160/210
25/24/180/225/250/280
320/360/440
Velocity
Damping
Setting
0%
50%
75%
75%
TC Adjust
Setting
0%
15%
30%
100%