Section II. Installation:
1. Remove the unit form its carton. Be sure to remove and discard all packing material. Place the
unit on a level surface with the grill side facing up.
2. Open the lid by depressing the button on the side of the unit. Lift the grill and remove the two
press-in plugs in the tracks for the grill arms.
3. Remove the grill arms by pushing the roller wheels through the track. Open the lid fully.
4. Remove the two screws holding the ground screen. Pull the screen out of the slots.
5. Using a 5/32" Allen wrench, remove the fan from the motor shaft.
6. Power to the unit can be run through one the electrical knock-outs provided in the cabinet. Follow
local electrical codes and ordinances.
7. The unit can now be mounted either partially recessed into a drop ceiling, with 4.25" exposed, or
fully exposed on a hard surface, with 9.25" of total depth exposed. The unit can be suspended
using threaded rod or chain and hooks, or can be mounted directly to a surface with lag bolts and
washers. The OH1010 can be mounted vertically on a wall.
23.75
2
23.75"