Dynamic RS4 Installatie-instructies en consumenteninformatie - Pagina 7
Blader online of download pdf Installatie-instructies en consumenteninformatie voor {categorie_naam} Dynamic RS4. Dynamic RS4 9 pagina's. Whole house iaq system
12) Close the cabinet access door and restore power to the furnace/air handler and UV air
purifier.
13) Switch the thermostat back to the "ON" position. For optimum results, the furnace or air
handler should be run continuously with the fan switch in the "ON" position, rather than
the "AUTO" position.
14) In damp or humid areas, the new media pad may make a slight snapping sound when first
installed. This is normal and should stop within 24 hours of operation.
WARNING: FAILURE TO CHANGE THE MEDIA PAD ON A REGULAR BASIS COULD REDUCE
AIRFLOW AND CAUSE DAMAGE TO THE HEATING AND COOLING SYSTEM.
Section VI. Maintenance – Activated Carbon Matrix
Carbon Matrix inserts generally last 18000 hours or two years, depending on household conditions.
Replacement carbon inserts are available from your heating and air conditioning contractor.
CAUTION: WHENEVER INSTALLING OR REMOVING THE AIR CLEANER, THE POWER TO THE
FURNACE/AIR HANDLER AND UV AIR PURIFIER SHOULD BE TURNED OFF. CARE SHOULD
BE TAKEN NOT TO LET THE JACK TOUCH ANY GROUNDED OR METAL SURFACES.
1) Turn the thermostat fan switch to the "OFF" position.
2) Turn off power to the furnace/air handler and UV air purifier.
3) Open the access panel on the RS4 cabinet.
4) Unplug the power cord from the air cleaner power supply.
5) Remove the air cleaner from the filter rack.
6) Open the air cleaner latches, carefully remove the old carbon inserts and discard.
7) Position the new carbon inserts so that they are centered within the frame (fig 7).
8) Close and re-latch the air cleaner.
9) Return the air cleaner to its location in the filter rack.
10) Plug the power supply cord into the air cleaner once it is securely in place (fig 6).
11) Close the cabinet access door and restore power to the furnace/air handler and UV air
purifier.
12) Switch the thermostat back to the "ON" position. For optimum results, the furnace or air
handler should be run continuously with the fan switch in the "ON" position, rather than
the "AUTO" position.
Section VII. Maintenance – UV Air Purifier
Series2 UV lamps are designed to last 18000 hours or two years, depending on household
conditions but should be cleaned after 9000 hours (1 year) of operation.
1) Cleaning Instructions:
a. Turn off power and disconnect power cord to the UV air purifier.
b. Remove the cover from the unit by removing the top and bottom retaining screws using a
screwdriver.
c. Unplug the lamp connector from the end of the lamp.
d. Remove lamp holder using a 11/32 size nut driver. (Figure B)
e. Remove the lamp by grasping the plastic end cap and extract carefully.
f. Using a soft cloth moistened with rubbing alcohol, wipe down the lamp. If there is a large
build-up of dust particles, you may wish to use a can of air first. Always handle lamp by
the end caps.
g. Slide the lamp back into lamp opening by grasping the plastic end cap and reinstall lamp
holder.
7