ADEMCO 6137 Installatiehandleiding - Pagina 2
Blader online of download pdf Installatiehandleiding voor {categorie_naam} ADEMCO 6137. ADEMCO 6137 2 pagina's. Remote keypads
Ook voor ADEMCO 6137: Gebruikershandleiding (9 pagina's), Beknopte handleiding (3 pagina's), Installatiehandleiding (2 pagina's), Installatiehandleiding (2 pagina's)
1.
Remove the case back by pushing down two "snaps" located
under the arrows in diagram on previous page .
2. Route wiring from the control panel through the opening in the
case back.
3. Mount the case back to a wall or electrical box.
4. Plug the supplied flying lead connector into the keypad PC
board and splice the panel wiring to it, or wire directly to the
terminal block on the PC board (wire colors are marked next to
Use the WIRING TABLE that matches
terminals).
the way the PCB is marked on the keypad your
connecting.
5. Reattach the keypad to its case back.
6. Remove the clear protective films from the LCD display and
keypad labels.
SETTING THE KEYPAD ADDRESS
The keypad can be set for an address of 0-31 (the keypad will not
accept entries greater than 31), which is stored in EEROM memory.
The keypad's default address is 31 (non-addressable mode–some
early versions of 6139/6139R default to 11).
To change the keypad's address, do the following:
1. Enter address mode: Power up (plug in) the keypad. Within 60
seconds of power-up, press and hold down the [1] and [3] keys at
the same time for 3 seconds. (If unable to enter address mode,
power up and try again.)
The current keypad address will be displayed, and the cursor
will be under the "tens" digit. If 10 seconds have passed with no
key entry, the keypad automatically exits address mode. You
must power down, power up and start address mode again.
NOTE: The keypad will not enter address mode if the panel to
which it is connected is in programming mode.
2. Set the current address to "00": Press [0] to clear the current
"tens" digit. The cursor will move to the "ones" digit position.
Press [0] to clear the current "ones" digit. The cursor will move
back to the "tens" digit position.
3. Enter the keypad's address: Enter the proper "tens" digit of the
keypad's address.
The cursor will move to the "ones" digit
position. Enter the proper "ones" digit of the keypad's address.
Note that address "31" sets the keypad to non-addressable
mode.
4. Exit address mode:
Press [✱] to save the displayed address and exit address mode.
REFER TO INSTALLATION INSTRUCTIONS FOR THE CONTROL PANEL FOR DETAILS ON LIMITATIONS OF THE ENTIRE ALARM SYSTEM.
Alarm Device Manufacturing Company, a Division of Pittway Corporation, and its divisions, subsidiaries and affiliates ("Seller"), 165 Eileen Way, Syosset, New York 11791, warrants its products
to be in conformance with its own plans and specifications and to be free from defects in materials and workmanship under normal use and service for 24 months from the date stamp control on
the product or, for products not having an Ademco date stamp, for 12 months from date of original purchase unless the installation instructions or catalog sets forth a shorter period, in which
case the shorter period shall apply. Seller's obligation shall be limited to repairing or replacing, at its option, free of charge for materials or labor, any product which is proved not in compliance
with Seller's specifications or proves defective in materials or workmanship under normal use and service. Seller shall have no obligation under this Limited Warranty or otherwise if the product
is altered or improperly repaired or serviced by anyone other than Ademco factory service. For warranty service, return product transportation prepaid, to Ademco Factory Service, 165 Eileen
Way, Syosset, New York 11791.
THERE ARE NO WARRANTIES, EXPRESS OR IMPLIED, OF MERCHANTABILITY, OR FITNESS FOR A PARTICULAR PURPOSE OR OTHERWISE, WHICH EXTEND BEYOND THE
DESCRIPTION ON THE FACE HEREOF. IN NO CASE SHALL SELLER BE LIABLE TO ANYONE FOR ANY CONSEQUENTIAL OR INCIDENTAL DAMAGES FOR BREACH OF THIS OR
ANY OTHER WARRANTY, EXPRESS OR IMPLIED, OR UPON ANY OTHER BASIS OF LIABILITY WHATSOEVER, EVEN IF THE LOSS OR DAMAGE IS CAUSED BY THE SELLER'S
OWN NEGLIGENCE OR FAULT.
Seller does not represent that the products it sells may not be compromised or circumvented; that the products will prevent any personal injury or property loss by burglary, robbery, fire or oth-
erwise; or that the products will in all cases provide adequate warning or protection. Customer understands that a properly installed and maintained alarm may only reduce the risk of a bur-
glary, robbery, fire or other events occurring without providing an alarm, but it is not insurance or a guarantee that such will not occur or that there will be no personal injury or property loss as
a result. CONSEQUENTLY, SELLER SHALL HAVE NO LIABILITY FOR ANY PERSONAL INJURY, PROPERTY DAMAGE OR OTHER LOSS BASED ON A CLAIM THE PRODUCT
FAILED TO GIVE WARNING. HOWEVER, IF SELLER IS HELD LIABLE, WHETHER DIRECTLY OR INDIRECTLY, FOR ANY LOSS OR DAMAGE ARISING UNDER THIS LIMITED
WARRANTY OR OTHERWISE, REGARDLESS OF CAUSE OR ORIGIN, SELLER'S MAXIMUM LIABILITY SHALL NOT IN ANY CASE EXCEED THE PURCHASE PRICE OF THE
PRODUCT, WHICH SHALL BE THE COMPLETE AND EXCLUSIVE REMEDY AGAINST SELLER. This warranty replaces any previous warranties and is the only warranty made by Seller on
this product. No increase or alteration, written or verbal, of the obligations of this Limited Warranty is authorized.
¬19l
N6752V9 2/03
VIEWING THE KEYPAD ADDRESS
Press and hold down the [1] and [3] keys at the same time for about
3 seconds.
allowed. Press any key to exit or wait 10 seconds to automatically
exit viewing mode.
WIRING TABLES
Wiring:
(all
Keypads)
8
+
9
SPECIFICATIONS
Physical:
6128: ...................... 4-3/4"H x 5-3/4"W x 1"D
6137/6137R: ............ 4-3/4"H x 6-1/4"W x 1"D
6138/6139/6139R: ... 4-3/4"H x 6-3/4"W x 1-1/4"D
Current:
6128: ..............45mA sounder on, 30mA standby, alarm sounder off.
6137/6137R: ..85mA (ARMED LED lit, LCD backlight and sounder
6139/6139R: ...100mA (ARMED LED lit, LCD backlight and
Displays:
6138: ..............1 x 16 alpha-numeric supertwist LCD, backlit.
6139,6139R: ...2 x 16 alpha-numeric supertwist LCD, backlit.
6128, 6137:.....Fixed-Word LCD (6137 backlit).
Sounder:.........Piezo-electric (fire alarm is loud, pulsing single tone;
(all Keypads) burglary alarm is loud, continuous, dual tone).
ADEMCO LIMITED WARRANTY
The current address is displayed.
Color
Function
Red
+12VDC
Black
Ground
Blue
If present, not used.
Green
Data to control panel.
Yellow
Data from control panel.
Keypad
Control Panel
G
Data Out
Data In
GND
Aux Pwr
+12VDC
+ Aux Pwr
Y
Data In
Data Out
on), reduces to 40mA when panel is operating in
standby mode (backlight off).
sounder on), reduces to 40mA when panel is
operating in standby mode (backlight off).
165 Eileen Way, Syosset, New York 11791
¤
Copyright
1993 PITTWAY CORPORATION
No key entry is
Color
Green
Black
Red
Yellow