1.General
These instructions are for correct installation, and optimum performance of the Bath
pumps, so they should be read carefully. These are single-stage centrifugal pumps
designed to operate with compact hydromassage equipment, They are equipped with
a total-emptying system to prevent the discharge of residual liquid in each stopping.
These units are designed to operate with clean water at a maximum water
temperature of 50℃.
Built of top quality materials, they are subjected to strict hydraulic and electrical
controls and are carefully verified.
Correct installation is ensured by following these instructions and those of the wiring
diagram; otherwise, over loads may be produced in the motor. We decline
responsibility for any damage caused by not following these instructions.
2.lnstallation
The pumps should be installed horizontally, securing them with screws through the
holes in the supports to prevent undesirable noise and vibration.
The suction, pipe of the pump should be as short as possible.
The rating Label must be visible after installation. Parts coutaining live parts, except
parts supplied with extra low voltage<12V, must be inaccessible to a person in the
bath. Class I appliances must be permanently connected to fixed wiring. Part
including electrical components except remote control devices must be located or
fixed so that they cannot into bath.
3.Pipe Assembly
The suction and discharge pipes should have a diameter equal to or greater than that
of the intake tapping of the pump.
Avoid traps as, in addition to affecting efficiency, they impede total overall emptying.
The suction and discharge pipes should not rest on the pump in any case.
Seal all the connectors and unions well. Avoid any dripping on the motor, which
would unfailingly damage it.
4.Electrical connection
The electrical install action should have a multiple separation system with contacts
opening at least 3mm.
For continued protection against possible electric shock this unit is to be mounted to
the base in accordance with the installation instrucions.
The protection of the system should be base on a residual current device (RCD) with
a rated tripping current not exceeding 30mA. The supply cable should comply with
EMC standards. Single-phase motors have built-in thermal protection. The electric
connection must be carried out by qualified stall following strivtly the "EN60335-2-41"
standard.
Be sure that the earth cable connection is correctly made.
Be sure that the equipotential connection between the bath and the pumo is corretly
made.
Wire serving as equipotential bonding conductors shall have a cross sectional area
between 2.5 and 6mm
2
and shall be equipped with the terminal suitable receptacle.
2