ADEMCO 5800GDO Installatie- en installatiehandleiding - Pagina 2

Blader online of download pdf Installatie- en installatiehandleiding voor {categorie_naam} ADEMCO 5800GDO. ADEMCO 5800GDO 4 pagina's.

5800GDO DIP Switch
Normal operation of the 5800 GDO requires all DIP switches be
in the OFF position.
DIP switch 1 – Enables the Erasing All RF Transmitters Mode.
Refer to Erasing All RF Transmitters Section.
DIP switch 2 – Enables the Enrolling RF Transmitters Mode.
Refer to Enrolling RF Transmitters Section.
DIP switch 3 – Used during Enrolling RF Transmitters Mode.
Refer to Enrolling RF Transmitters section.
DIP switch 4 – 6 Used during Erasing All RF Transmitters
1
2
ON
OFF
ENROLLING RF TRANSMITTERS
Notes:
To exit the Enrolling RF Transmitters Mode at any
time, set DIP switch 2 to the OFF position.
Unless
otherwise
automatically exit the Enrolling RF Transmitters
Mode if each step is not accomplished within one
minute of the other.
If during the enrollment procedure excessive RF
interference is noted as indicated by the RF
Interference Indicator LED, it is advised that
enrollment be exited until free of RF interference.
This will prevent inadvertent enrollment of an
outside wireless transmitter device.
1.
Set all DIP switches to the OFF position.
2.
Place DIP switch 2 in the ON position.
3.
Disconnect/reconnect power to the 5800GDO.
Immediately after power is applied the following will
occur:
The green LED will turn on and remain on.
If the EEPROM is not full, the red LED will flash on
and off once for each transmitter that can still be
enrolled and then lights steady.
If the EEPROM is full (8 wireless keys enrolled), the
red LED will remain on, indicating that no more
transmitters can be enrolled.
4.
If enrolling:
An encrypted transmitter (i.e. 5804E and
a.
5804WATCH), press and hold all 4 buttons at
the same time. Verify the red LED turns off.
A
bi-directional
b.
5804BDV), press and hold the B, C, & D buttons
at the same time. Verify the red LED turns off.
A
non-encrypted
c.
5804BD), press the button to be enrolled twice.
Verify the red LED turns off.
5.
Place DIP switch 3 in the ON position.
6.
Press and release the button that will be used to
operate the garage door. Verify the red LED flashes
3 times.
3
4
5
6
5800GDO-002-V0
noted,
the
5800GDO
encrypted
transmitter
transmitter
(i.e.,
Note: If an incorrect wireless transmitter is enrolled,
set DIP switch 3 to OFF and repeat the enrollment
procedure from step 4.
7.
To add an additional button on the same key, repeat
step 6 for that button.
8.
Place DIP switch 3 in the OFF position to accept the
button(s) enrolled.
9.
Repeat steps 4 through 8 to enroll additional
wireless transmitters.
10. When all devices are enrolled, place DIP switch 2 in
the OFF position.
ERASING ALL RF TRANSMITTERS
Notes:
To exit this procedure at any time, set DIP switch 1
to the OFF position and wait 5 seconds before
restarting procedure.
Unless
automatically exit the Erasing All RF Transmitters
Mode if each step is not accomplished within one
will
minute of the other
1.
Place DIP switch 1 in the ON position.
2.
Disconnect/reconnect power to the 5800GDO.
Immediately after power is applied the following will
occur:
The green LED will turn on and remain on.
If the EEPROM is not full, the red LED will flash on
and off once for each transmitter that can still be
enrolled and then lights steady.
If the EEPROM is full (8 wireless keys enrolled), the
red LED remain on, indicating no more transmitters
can be enrolled.
3.
Place all DIP switches opposite to their current
position within one minute of applying power in step
2. (All DIP switches must be switched opposite to
their current position within 5 seconds of each other
to avoid exiting this procedure.)
4.
Return all DIP switches to their original positions
and verify the red LED turns off.
When the red LED turns off, all transmitters have
been erased.
SPECIFICATIONS
Dimensions:
2-3/4" W x 4-15/16" H x 1-1/16" D.
(70mm x 125mm x 27mm)
Voltage:
(i.e.
12VDC OR
9VAC, 15VA (use ADEMCO 1332 or equivalent)
Current:
5804,
60mA
Relay:
One relay, with choice of normally open or normally
closed operation.
Contact Ratings: 2 Amps at 28VDC.
Operating Temperature:
32° - 122°F (0° - 50°C)
2
otherwise
noted,
the
5800GDO
will