1. Fiberglass Filter Parameters
Model
Filter Model
HT-VC400-6W
HT-V400
HT-VC450-6W
HT-V450
HT-VC525-6W
HT-V525
HT-VC625-6W
HT-V625

2. Installation

Install filtration system including pump,filer tank and multiport valve.
The filter system should be installed as close as possible to the swimming pool and preferably at a leve of
0.50 metres below the surface of the water in the swimming pool. Make sure there is drainage available at the
place where the filter is to be installed.
PUMP
1.Only qualified, licensed personnel should install pump and wiring.
2.Electrical Contractors Please Note: All 220 volt 50 HZ pump must be wired to the main power supply trough
an approved and correctly rated contractor.
3.Allow for gate valve in suction piping.
4.Pump suction and discharge connections have moulder in thread stops, do not try to screw pipe in beyond
these stops.
FILTER TANK AND MULTIPORT VALVE
1.Loading the sand media.Filter sand media is loaded through the top opening of the filter.
a.Lossen the plastic clamps from tank neck.
b.Cap internal pipe with plastic cap to prevent sand from entering it.
c.We recommend filling tank approximately 1/2 way with water to provide a cushion effect when the filter
sand is poured in. This helps protect the under-drain laterals from excessive shock.
d.Carefully pour in correct amount and grade of filter sand. Be sure center pipe remains centered in
opening.Sand surface should be leveled and should come to about the middle of the filter tank. Remove
plastic cap from internal pipe.
2.Assemble filter control valve to filter tank.
a.Insert filter control valve(with O-ring in place)into the tank neck,taking care that the center pipe slips into the
hole in the bottom of the valve.
b.Place two plastic clamps around valve flange and tank neck and tighten just enough so that the valve may
Be rotated on tank for final positioning.
c.Carefully screw pressure gauge(with O-ring in place)into tapped hole in valve body.Do not over-
tighten.Connect pump to control valve opening marked PUMP with hose.After connections are made,tighten
clamps with screwdrive,tapping around clamp with screwdrive handle to help seat valve flange clamp.
3.Make return to pool pipe connection to control valve opening marked RETURN and complete other
necessary plumbing connections,suction lines to pump,waste,etc.
4.To prevent water leakage,be sure all pipe connections are tight.
Pump Model
Valve Connectio
Hidro-BPS050
1.5
Hidro-BPS050
1.5
Hidro-BPS075
1.5
Hidro-BPS100
1.5
Figure 1
0.5-0.8mm
Sand Weight
50mm
35Kg
50mm
45Kg
50mm
85Kg
50mm
150Kg
Flow Rate
3
8m
/h
3
10m
/h
3
12m
/h
3
16m
/h