OPERATION

To start your generator with gasoline

1. Make sure no electrical devices are connected to the generator. Such devices can make it difficult for the engine
to start.
2. Check the hose valve is connected to liquid propane gas supply and if so, shut it off.
3. Check generator is properly grounded.
4. Turn the fuel valve to "on" position.
5. Move choke lever to the "closed" position, or pull out choke lever.
6. Turn engine switch to "ON" position, PUSH "Start" button, not more than 15 seconds for every time, if succeed,
release the button, if fail, have a second try in the same way. If the engine doesn't work when you push start
button, please try to start with recoil starter.
7. Pull on the recoil starter handle slowly until a slight resistance is felt. Then pull quickly to start the engine. Return
cord gently into the machine. Never allow the cord to snap back.
8. If engine fails to start, repeat step 6. NOTE: After repeated failed attempts to start the engine, please consult the
troubleshooting guide before attempting again.
9. Once the engine has started, move the choke lever about half way towards the "open" position. Wait 30 seconds
and then move the choke lever all the way to the "open" position.
10. Allow the generator to run for several minutes before attempting to connect any electrical devices.

To start your generator with liquid propane gas

1. Shut off the fuel valve.
2. Connect the hose valve to liquid propane gas supply,
3. Check there is no load in any receptacle.
4. For first use of generator, do not need operate the following item 5 and 6.
5. Start the engine (by recoil start, push button start).
6. Use up the remained fuel inside engine and it will shut down automatically.
7. Turn on the liquid propane gas valve.
8. Start engine and run at least one minute, then connect to electrical loads.

Stopping the generator

1. Disconnect all loads to the generator
2. Turn OFF AC circuit breaker
3. Turn OFF engine switch located on control panel
4. Turn gasoline line shut-off valve to OFF (horizontal position). Or turn propane tank valve off if generator running
with liquid propane fuel, or turn OFF nature gas valve if generator running with nature gas.

CAUTION

1. Remained fuel inside engine may cause engine difficult to start or out of normal running after starting.
2. Before changing liquid propane gas supply shut off all connected electrical devices and generator.
3. Normal working pressure is 2kpa-1Mkpa.
5