Note:
All cables to be connected prior to turning the power on. The pre-
amplifier, crossover network or any other equipment shall be
turned on prior to the power amplifier.
SIGNAL INPUT AND OUTPUT TERMINALS:
This power amplifier is equipped with electronically balanced inputs using XLR-terminals (female).
Pin allocation is as follows:
• Pin 1 = GND/shield
• Pin 2 = signal (+) in phase
• Pin 3 = signal (-) anti-phase
DPA 6.4 also has a set of (L and R channels) XLR-terminals (male) in parallel with the input terminals.
These terminals shall be used when paralleling L and R channels or paralleling several DPA 6.4s. A
specially prepared cable shall be used when paralleling or bridging DPA 6.4s, see pages 7 and 8.
LOUDSPEAKER TERMINALS:
The amplifier is equipped with 4 sets of binding post (screw fastening terminals).
FUSES:
A defective fuse shall only be replaced by an equivalent fuse.
Using a fuse with an incorrect value can cause serious damage to the amplifier which is not
covered by the warranty, and could start a fire.
DPA 6.4
CABLES AND CONNECTIONS
Figure 2. DPA 6.4 back panel.
CONNECTIONS
6
PAGE