ELECTRICAL CONNECTIONS

WARNING: To avoid possible electrical shock be sure electricity is turned off at the main fuse or breaker box before
wiring.
NOTE: The Aire Control® System for this DC motor fans is equipped with a learning frequency function which has 32
code combinations to prevent potential interference from other remote units. The frequency on your Receiver and
Transmitter units have been preset at the factory. (Fig. 11) No frequency change is necessary, should you desire to
install another Minka Aire DC motor fan within the same home or area with a separate frequency code please see the
"frequency interference" troubleshooting section of this instruction manual to learn how to change the frequency.
The "D (DIMMER)" selection is the light dimmable selection and is to be used with all bulbs except for CFL bulbs. The
"ON (ON/OFF)" selection is the light on only (no dimming function) and is to be used with CFL bulbs as CFL bulbs cannot
be dimmed properly.
Step 1. Motor to House Supply Wires Electrical Connections: Connect the WHITE wire (Neutral) from the outlet box to the
WHITE wire marked "AC in N" from the motor. Connect the BLACK wire (Hot) from the outlet box to the BLACK wire
marked "AC in L" from the motor. Secure all wire connections with the plastic wire nuts provided. (Fig. 12)
Step 2. If your outlet box has a GROUND wire (Green or Bare Copper) connect this wire to the Hanger Ball and Hanger
Bracket Ground wires. If your outlet box does not have a Ground Wire, then connect the Hanger Ball and Hanger Bracket
Ground Wires together. Secure wire connection with the plastic wire nut provided. (Fig. 12)
After all splices are made, check to make sure there are no loose strands. As an additional precaution we suggest to
secure the plastic wire connectors to the wires with electrical tape.
FREQUENCY
FIG. 11
BLACK (HOT)
WHITE (NEUTRAL)
WHITE ("AC IN N")
FIG. 12
8
GREEN OR BARE
COPPER (GROUND)
(CONNECT TO
GROUND
GROUND WIRE
(GREEN)
ON HANGER
BRACKE IF NO
HOUSE GROUND
WIRE EXISTS.)