Auton 3000-INV Installatiehandleiding - Pagina 5

Blader online of download pdf Installatiehandleiding voor {categorie_naam} Auton 3000-INV. Auton 3000-INV 6 pagina's.

Continued
Adjust Motor and Limit Switch Continued
Limit switches are preset at the factory for optimal positioning and performance, but they may be changed.
Two adjusting screws for the limit are located at the end of the motor. The top screw controls the open
travel , the bottom screw controls the closed travel.
Using a power tool to adjust the limits will void the warranty.
1. to increase open travel:
down travel.
2. to increase closed travel:
down travel.
3.
Run the lift in the opposite direction for approximately 6" and stop. The motor will recognize the adjustment.
NOTE:
When adjusting the limit switches, turn the adjusting screw in very small increments so
over-adjustment doesn't occur. Each full turn of the screw corresponds to 3/8" in travel.
*The motor is equipped with a built-in thermal overload protection system. In the event the lift (motor) is moved
too frequently in a short period of time, the unit will be disabled to prevent overheating and possible damage.
The unit will automatically re-set itself within 10-15 minutes.
caution:
Dropping or jarring unit by hitting walls, ceilings,
or other objects may cause misalignment of lift.
-
+
-
+
turn the top screw clockwise; turn counter-clockwise to decrease the
bottom
turn the
screw clockwise; turn counter-clockwise to decrease the