Galactron MK 2225 Gebruikershandleiding - Pagina 7

Blader online of download pdf Gebruikershandleiding voor {categorie_naam} Galactron MK 2225. Galactron MK 2225 10 pagina's.

The volume control is done using the two buttons on the remote control or by turning the knob in the center,
on the front panel. The adjustment of the volume has been divided into forty-eight steps, very close together
when there is little attenuation, and progressively increasing hand in hand that the signal is attenuated.
The maximum attenuation possible before the last shot is -48 dB; taking the last shot because the total
silencing.
When you press one of the volume control buttons on the remote control, the front panel will illuminate on
and the arrow that indicates whether the level is climbing or descending. Arriving at the maximum
attenuation or maximum exaltation written and arrows do not light up anymore, indicating that they have
been reached the limits of adjustment.
Press "MUTING", when pressed on the remote, due to the lowering of instantaneous output level of 20 dB.
To return to the original level is sufficient to press the switch.
TURNING OFF THE AMPLIFIER
To put the amplifier in STAND-BY, and just press on the remote control simultaneously the keys (+ / -).
To turn off the amplifier you must first press the right button on the front panel and then subsequently lead to
the OFF position the switch on the rear panel. The microprocessor control provides first a short circuit by the
output signal from the preamplifier, so as to prevent impulsive noise, then deactivates the relay that supplies
power to the power supply main: at this point all the lights on the panel are turned off.
WARNING: NEVER TURN OFF THE AMPLIFIER WITH THE MAIN LINE SUPPLY POWER
SWITCH BEFORE HAVING PLACED THE UNIT IN STAND-BY. THIS ERRONEUS
PROCEDURE WILL CAUSE VIOLENT TRANSIENT AT THE AMPLIFIER OUTPUT, WITH
POTENTIALLY DANGEROUS EFFECTS ON THE SPEAKERS.
The main power switch is turned on, but the POWER LED is not illuminated.
The wall outlet is not powered.
the mains supply voltage is supplied to the machine
The fuse to the microprocessor has blown*.
The POWER LED is burned out
The microprocessor has failed.
The POWER LED is illuminated but the amplifier does not respond to the remote control.
The batteries in the remote control unit are dead.
The remote control unit has malfunctioned.
the infrared detector has failed.
The amplifier goes ON normally, but no sound is produced by the speakers.
The program source is not connected correctly.
The source is not functioning properly,

TROUBLESHOOTING

Check that the correct voltage is presents at the end of the power cord. If
Turn off the amplifier, disconnect the cord from the wall socket,
remove the fuse from its holder and check for continuity.
If the fuse is in good condition,
Try to activate the amplifier using the remote control. If there is not
action,
The infrared detector on the amplifier is obstructed, or it is placed at an
angle greater than 30° with respect to the remote control.
Check that the amplifier is in correct position.
If the amplifier is in the correct position,
Check the battery charge level, and replace as required.
If the battery are charged,
Try setting the amplifier with another remote control of the same
type.
If the unit still does not work properly,
Check that the input selected is correctly connected to the audio
source.
If the connections are correct,
7