Galanz DC-80S1U Servicehandleiding - Pagina 16
Blader online of download pdf Servicehandleiding voor {categorie_naam} Galanz DC-80S1U. Galanz DC-80S1U 17 pagina's. Condensing dryer
Selection procedure error diagnosis
(1)Condition
①Under the state of programme selected, the system selects programme
which is not selected.
②Stall switch changes switch during normal operation.
(2)system reaction
The digital tube displays fault code "Ers", then it displays the setting time or the
time rest. If the digital tube flashes the fault code while the Buzzer function is on,
then the system will Buzz the alarm.
(E6)Condenser malfunction diagnosis
(1)Condition: Condenser is removed
(2)System reaction
All the selected programmes stop. "Condenser"indicator light flashes. Digital tube
displays fault code "E6". All of the buttons and stall switch have no reaction.
Whether the Buzzer is on or not, it will raise the Error alarm for 5 seconds every 5
minutes.
Water tank diagnosis
(1)Condition: The water in tank is full
(2)system reaction
All the programmes stop. System gets into the state of suspension, and the "Tank"
flashes in the digital indicator light.
10 Malfunction Code
fault
E1
code
temperature
sensor
fault
open-circuit
or
short-circuit
E2
E3
heating wire
temperature
Heating
sensor
wire not
open-circuit
working
or
short-circuit
dOP
ErS
selection
door is
procedure
opening
error
16
E6
Condenser
is removed