Autonics SFC Series Handmatig - Pagina 12
Blader online of download pdf Handmatig voor {categorie_naam} Autonics SFC Series. Autonics SFC Series 13 pagina's. Safety controllers / safety relay unit
Ook voor Autonics SFC Series: Handmatig (13 pagina's)

Connection Examples 6
■ Relay unit-Safety light curtain
Connections
Safety controller: Relay unit SFC-R412
Safety light curtain: SFL / SFLA Series
Contactor of rated load (from Annex C of ISO 13849-1)
SFL(A) Series
Emitter
GND
OSSD1
SFL(A) Series
Receiver
OSSD2
MC4
MC3
MC2
MC1
MC3
MC1
MC2
MC4
M2
M1
MC1 to MC4: Magnetic contactor
M1, M2: 3-phase motor
• Operation timing chart
Safety light
curtain
MC1 to MC4 b contact
MC1 to MC4 a contact
• For more information on wiring and detailed settings for safety light curtain (SFL/SFLA Series), refer to the "
• The control output of the safety light curtain (SFL(A) series) is based on the PNP output.
Start
PL/Safety category
Auto
PLe/Cat.4 equivalent
24V
Safety controller: Relay unit
FUSE
A1
Power
A2
M11
NC
Safety Input 1
M12
M21
NC
Safety Input 2
M22
M51
Feedback
M52
Start Input
M53
Auxiliary Output
Safety Relay Output
13
23
33
43
X1
PLC etc.
GND
14
MC1
24
MC2
34
MC3
44
MC4
SFL/SFLA user manual.
"