AMPLIFIER FEATURE DESCRIPTIONS

TITAN TXi SERIES AMPLIFIERS:
Each model is capable of 4 & 2-Ohms stereo per channel, or 4-Ohms mono bridged operation
except the mono amps which are capable of 4, 2 and 1-Ohm loads.
Tri-Mode operation with any stereo pair of amplifier channels is possible, as with all bridgeable
amplifiers.
The input sensitivities for rated output powers are listed below for each model.
All crossovers are fully variable in their respective ranges.
Crossover filters are 12dB/Octave.
A POWER LED indicates the powered up and turned on condition.
The X-OVER slide switch selects the internal crossover functions:
-The input signal is routed directly to the LINE OUT RCA jacks, regardless of the X-OVER setting
simplifying daisy chaining of amplifiers.
-HPF: Selects the built in HIGH PASS filter, variable from 60 Hz to 1.2kHz.
-FULL: Bypasses all crossovers for full frequency range operation.
-LPF: Selects the built in LOW PASS , variable from 30 Hz to 250Hz.
MODE: The mode switch allows you to choose Stereo for full range 2 channel operation or MONO
for bridging operation
HIGH INPUT: If your radio/CD player does not have unbalanced (RCA) outputs, you can use the
HIGH level (wire) inputs.
LINE INPUT: The line input accepts unbalanced (RCA) inputs from 0.2V to 5V.
LINE OUTPUT: The line output passes through signal from the line inputs which allows you to daisy
chain multiple amplifiers from one signal.
The 4 channel amps have the same features as the 2 channel models accept that there are 2 sets of
controls.
1 set for channels 1 & 2 and 1 set for channels 3 & 4.
In addition, the 4 channel models have a Mode switch which allows you to select 2, 3 or 4 channel
operation.
The X-OVER slide switch selects the internal crossover functions:
-The input signal is routed directly to the LINE OUT RCA jacks, regardless of the X-OVER setting
simplifying daisy chaining of amplifiers.
-HPF: Selects the built in HIGH PASS filter, variable from 60 Hz to 1.2kHz.
-FULL: Bypasses all crossovers for full frequency range operation.
-LPF: Selects the built in LOW PASS , variable from 30 Hz to 250Hz.
MODE: The mode switch allows you to choose Stereo for full range 2 channel operation or MONO
for bridging operation
HIGH INPUT: If your radio/CD player does not have unbalanced (RCA) outputs, you can use the
HIGH level (wire) inputs.
LINE INPUT: The line input accepts unbalanced (RCA) inputs from 0.2V to 5V.
LINE OUTPUT: The line output passes through signal from the line inputs which allows you to daisy
chain multiple amplifiers from one signal.
LINE INPUT: Accepts unbalanced RCA inputs from 0.2 volts to 6 volts.
LEVEL: The input level control allows you to match the amplifier input sensitivity to the output level of
the RADIO/CD source from 0.2 volts to 6 volts.
REMOTE: The RJ45 Remote jack accepts the Bass Remote Module.
BASS EQ: The Bass Boost is fully adjustable from 0 to 12dB at 45Hz.
SUBSONIC: The variable Subsonic filter is fully adjustable from 15Hz to 55Hz.
LPF: The built-in low pass frequencies are fully variable from 40 to 150Hz.
POWER: Indicates that the amp has power, ground and remote turn-on input via a green L.E.D.
PROTECT: Indicates that the amplifier has detected a fault and will not operate. There are several
possible problems that can cause the amplifier to go into the protect mode. See the trouble
shooting guide in the back of the manual for details.
-The LINE INPUT signal is routed directly to the LINE OUT RCA jacks, regardless of the X-OVER
setting simplifying daisy chaining of amplifiers.
-SUBSONIC: Allows you to adjust the crossover filter from 15Hz to 35Hz.
-LPF: Allows yo to adjust the LOW PASS crossover filter from 35Hz to 250Hz.
LEVEL: Adjusts the input sensitivity from 0.2 volts to 9 volts.
BASS EQ: The Bass EQ is adjustable from 0dB to 10dB.
REMOTE: This is the input jack for the under-dash bass remote module.
LINE INPUT: The line input accepts unbalanced (RCA) inputs from 0.2V to 9V.
LINE OUTPUT: The line output passes through signal from the line inputs which allows you to daisy
chain multiple amplifiers from one signal.
All Hifonics amplifiers feature a comprehensive diagnostic system, with speaker lead short circuit,
and amplifier DC faults indicated by the red "PROTECT" LED.
CAUTION: DO NOT OPERATE ANY AMPLIFIER BELOW THE INTENDED IMPEDANCE.. YOU
WILL CAUSE DAMAGE TO THE AMPLIFIER THAT WILL NOT BE COVERED UNDER THE
WARRANTY PRINTED IN THE BACK OF THE MANUAL. 2 & 4 Channel amps are capable of 4
and 2-Ohms wired stereo and 4-Ohms wired mono bridged. The mono amps are capable of 4, 2
and 1-Ohm.
TXi4008 / TXi6008 2-CHANNEL AMPLIFIERS
LINE OUT LINE INPUT
LEVEL
BASS EQ
L
L
+ - gnd - +
HI INPUT
5V 0.2V
0dB 12dB
R
R
Note that the LOW PASS signal is MONO.
-In the LPF position, the HIGH PASS filter acts as a subsonic
filter.
-When the LPF mode is selected, a 0 to +12dB, at 45Hz, BASS
-EQ is also switched in.
TXi4408 / TXi6408 4-CHANNEL AMPLIFIERS
LEVEL BASS EQ HPF
CH3
CH4
LINE INPUT
R
+ - gnd - +
5V 0.2V
0dB 12dB 60Hz 1.2KHz 30Hz 250Hz
HI INPUT
LEVEL BASS EQ HPF
+ - gnd - +
L
CH3/4
CH1/2
CH1
CH2
5V 0.2V
0dB 12dB 60Hz 1.2KHz 30Hz 250Hz
Note that the LOW PASS signal is MONO.
-In the LPF position, the HIGH PASS filter acts as a subsonic
filter.
-When the LPF mode is selected, a 0 to +12dB, at 45Hz, BASS
-EQ is also switched in.
TXi7508 1-CHANNEL A/B-CLASS MONO AMPLIFIERS
REMOTE
CONTROL
BASS EQ
POWER
PROTECT
0dB 12dB
15Hz 55Hz
The mono amps are capable of 4, 2 & 1-Ohm loads.
Operating the amp below 1-Ohm can cause damage to the
amp not covered in the warranty.
TXi1008D / TXi1508D 1-CHANNEL D-CLASS MONO BLOCK AMPLIFIERS
INPUT
OUTPUT
BALANCED
LEVEL
PHASE
INPUT
L
L
9V
0.2V 0
R
R
The mono amps are capable of 4, 2 & 1-Ohm loads.
Operating the amp below 1-Ohm can cause damage to the
amp not covered in the warranty.
HPF
LPF
X-OVER
MODE
FULL LPF HPF MONO
STEREO
60Hz 1.2KHz 30Hz 250Hz
CHANNEL 3 / 4
LPF
LINE OUTPUT
X-OVER
MODE
2 3 4
FULL LPF HPF
CHANNEL
LPF
X-OVER
FULL LPF HPF
CHANNEL 1 / 2
OUTPUT INPUT
SUB
SONIC
LPF
LEVEL
L
40Hz 150Hz
6V
0.2V
R
REMOTE
BASS EQ
SUBSONIC
LOW PASS
180
0dB 10dB
15
35Hz
35
250Hz PRO
R
L
PWR